SRE-2010E OPERATOR 01-14-2022
8
Bruno Independent Living Aids, Inc.
BATTERY CHARGER LEDS
Battery
charger
RED YELLOW GREEN BLUE STATUS
ON ON (< 1 sec.)
OFF
OFF OFF charger not connected to bat-
tery
ON (<5 sec.)
ON
ON
ON (<5 sec.)
OFF
OFF
ON (<5 sec.)
BLINK (5 sec.)
OFF
OFF battery disconnect situation
detected; 5-second delay until
yellow and green LED’s
completely o
ON ON OFF OFF charger delivering maximum
current (2.2A)
ON ON OFF OFF charger at maximum voltage;
current continues to drop
ON OFF ON OFF batteries fully charged;
yellow LED occasionally turns o
ON BLINKS
ALTERNATELY
BLINKS
ALTERNATELY
OFF low voltage indication
BLINKS
ALTERNATELY
BLINKS
ALTERNATELY
OFF OFF battery defective or heavily
sulfated
ON OFF FAST BLINK OFF partially open circuit; bad
contact or battery sulfation
ON battery connector reversed
Note: The battery charger is designed to be mounted in a
temperature-controlled, dry location. If it has to be exposed to
water, do not use until inspected.