N
Nathan LozanoAug 15, 2025
What to do if the Bryant Furnace door switch is not closed?
- MMark ZavalaAug 15, 2025
If the door switch on your Bryant Furnace is not closed, replace the door switch.
What to do if the Bryant Furnace door switch is not closed?
If the door switch on your Bryant Furnace is not closed, replace the door switch.
How to fix Bryant 310AAV Furnace if the LED status light is off?
If the LED status light on your Bryant Furnace is not on, replace the furnace control.
What to do if the thermostat is not compatible with the Bryant 310AAV Furnace?
If the thermostat is not compatible with the Bryant Furnace control, you can install a ballast resistor, connect the Com24V thermostat terminal to the thermostat, or replace the thermostat.
What to do if the Bryant Furnace control doesn't respond to thermostat signals?
If the control of your Bryant Furnace does not respond to W, Y1 (if present), Y/Y2 or G (24V) thermostat signals, run the system through a heating or cooling cycle to check its operation.
What to do if the Bryant Furnace thermostat is not compatible?
If your Bryant Furnace's thermostat isn't compatible with the furnace control, you can either install a ballast resistor, connect the Com24V thermostat terminal to the thermostat, or replace the thermostat.
What to do if the Bryant 310AAV problem repeats with a jumper wire?
If the problem repeats in your Bryant Furnace when using a jumper wire, replace the furnace control.
What to do if the problem repeats when using a jumper wire on Bryant 310AAV?
If the problem repeats when using a jumper wire on your Bryant Furnace, replace the furnace control.
What to do if there is no 115V at L1 and L2 on Bryant 310AAV?
If there is no 115V at L1 and L2, replace the door switch on your Bryant Furnace.
What to check if the circuit breaker isn't closed on my Bryant 310AAV?
If the circuit breaker is not closed on your Bryant Furnace, check for correct line voltage polarity.
What to do if there is no 24V at SEC-1 and SEC-2 on my Bryant Furnace?
If there is no 24V at SEC-1 and SEC-2 on your Bryant Furnace, check for continuity in the wire from the circuit breaker to the furnace.
Model | 310AAV |
---|---|
Type | Gas Furnace |
Efficiency Rating | High Efficiency |
Blower Type | Multi-speed |
Stages | Single-stage |
Efficiency | 80% AFUE |
AFUE Rating | 80% |
Ignition System | Hot Surface Ignition |
Heating Capacity | 40, 000 to 120, 000 BTU/h |
Fuel Type | Natural Gas |
Warranty | 10-Year Parts Limited Warranty upon timely registration |
Warranty on Parts | 10-Year Parts Limited Warranty upon timely registration |
Warranty on Heat Exchanger | 20-year limited warranty |