Form No. PDS 581B.36.5
COMMERCIAL
SINGLE PACKAGE ROOFTOP
GAS HEAT/ELECTRIC COOLING
UNITS
Bryant has designed the DuraPac Plus series based on
customer needs and requests to be the most efficient and reli-
able ever.
FEATURES/BENEFITS
Efficient rooftop line for cooling using scroll compressor
technology
Efficient rooftop line for heating using dimpled heat
exchangers
High reliability — non-corrosive condensate pans, prepainted
cabinets and primed interior panels, and all units are fully
protected by internal safeties
Quiet operation — isolated compressor plate. All compres-
sors mounted on independent vibration isolators. Standard,
belt-driven evaporator fan motors on all units
Ease of maintenance achieved by self diagnostics on the
Integrated Gas Controller (IGC), standard size filters, no tool
filter access, simple compressor access, permanently lubri-
cated fan motors, optional disconnect switch, optional hinged
access panels, and optional 115-v convenience outlet
Performance and comfort enhancing options — High-static
motors and Perfect Humidity™ dehumidification package.
BRYANT MEANS TOP QUALITY AND RELIABILITY —
Each component utilized in the DuraPac Plus series is
designed and tested for a minimum of 15 years operation
under the harshest conditions.
Every unit is thoroughly run tested at the factory in each oper-
ating mode and evacuated prior to final charging. Every coil is
leak-tested with helium particles. Automated run testing allows
accurate undisputed tests and measurements which are sec-
ond to none in the industry.
Each unit contains a factory printout indicating tested pres-
sures, amperages, dates, and inspectors, providing certifica-
tion of the unit’s status at the time of manufacture.
Units are equipped with valuable safety controls designed to
monitor and protect for the life of the unit. The standard safe-
ties include:
low-pressure/loss-of-charge switch
high-pressure switch
freeze-protection thermostat
internal compressor overload
exclusive Cycle-LOC™ circuit board that prevents compres-
sor cycling
refrigerant filter drier
The cabinet is constructed of galvanized steel, bonderized and
coated with a prepainted baked enamel finish. The paint finish
is a non-chalking type, and is capable of exceeding Federal
Test Method Standard No. 141 (Method 6061) 500-Hour Salt
Spray Test. In addition, all cabinet interior surfaces are primed,
allowing the entire unit to have a longer life and more attractive
appearance.
EASY MAINTENANCE AND INSTALLATION
All Units are Factory Shipped in the Vertical Discharge
Configuration
for fit-up to standard roof curbs. (One acces-
sory curb fits sizes 036-072; another accessory curb fits
sizes 090-150.) Contractors can order and install the roof curbs
early in the construction stage, before decisions on size
requirements have been made.
All Units Feature Heavy-Gage Roll-Formed Baserail
design
with forklift slots on 3 sides of the unit and rigging holes for
easier maneuvering and installation. Stretch-wrap packaging
protects the unit during shipment and storage.
Units are Easily Converted
from vertical to horizontal applica-
tions to make retrofit and add-on jobs easier. To convert from
vertical to horizontal discharge, simply relocate 2 panels. The
same basic unit can be used for a variety of applications and
can be quickly modified at the jobsite.
Standard high-performance, belt-driven, evaporator-fan motors
enable 581B036-150 units to operate in most ductwork
configurations.
Ductwork Connections are Made Easy
by the logical 2 to 1
aspect ratio. On vertical discharge units, ductwork attaches
directly to the roof curb.
Model 581B
Dura
Pac
Plus Series
Sizes 036-150
3 to 12
1
/
2
Tons
Unit 581B036-072
Unit 581B090-150

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bryant COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEAT/ELECTRIC COOLING 581B and is the answer not in the manual?

Bryant COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEAT/ELECTRIC COOLING 581B Specifications

General IconGeneral
Model581B
TypeSingle Package Rooftop
Heating TypeGas Heat
Cooling TypeElectric Cooling
RefrigerantR-410A
Power Supply460-3-60
DimensionsVaries by specific model size

Summary

COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEAT/ELECTRIC COOLING UNITS

FEATURES/BENEFITS

Bryant Means Top Quality and Reliability

Emphasizes the durability and testing standards of the DuraPac Plus series components.

Easy Maintenance and Installation

Details features facilitating easy maintenance, installation, and conversion.

FEATURES/BENEFITS (cont)

Quiet, Efficient Operation and Dependable Performance

Discusses the quiet operation, efficiency, and reliability of the unit's components.

Serviceability

Highlights standardized components and features that enhance serviceability and parts availability.

Integrated Gas Unit Controller (IGC)

Details the IGC's functions, diagnostics, and benefits for heating operation.

MODEL NUMBER NOMENCLATURE

OPTIONS AND ACCESSORIES

OPTIONS AND ACCESSORIES (cont)

Perfect Humidity™ Dehumidification Package

Describes the package for increased dehumidification by subcooling refrigerant.

PHYSICAL DATA (cont)

Furnace Section

Provides furnace section data like rollout switch, orifice diameter, gas input, and efficiency for larger units.

BASE UNIT DIMENSIONS

BASE UNIT DIMENSIONS (cont)

SELECTION PROCEDURE (With 581B048 Example)

Determine Cooling and Heating Requirements at Design Conditions

Outlines the initial step in selecting a unit, defining design conditions.

Select Unit Based on Required Cooling Capacity

Guides selecting the appropriate unit based on cooling capacity tables.

Determine Fan Speed and Power Requirements at Design Conditions

Details calculating fan speed and power needs based on static pressure.

PERFORMANCE DATA

Cooling Capacities (581B036 (3 TONS))

Presents cooling capacity data (TC, SHC, kW) for 3-ton units at various temperatures.

Cooling Capacities (581B048 (4 TONS))

Presents cooling capacity data (TC, SHC, kW) for 4-ton units at various temperatures.

PERFORMANCE DATA (cont)

Cooling Capacities (581B060 (5 TONS))

Presents cooling capacity data (TC, SHC, kW) for 5-ton units at various temperatures.

Cooling Capacities (581B090 (71/2 TONS))

Presents cooling capacity data (TC, SHC, kW) for 7.5-ton units at various temperatures.

Cooling Capacities (581B120 (10 TONS))

Presents cooling capacity data (TC, SHC, kW) for 10-ton units at various temperatures.

Cooling Capacities, Units With Perfect Humidity™™ Option (581B036 (3 TONS))

Cooling capacity data for 3-ton units with Perfect Humidity option.

Cooling Capacities, Units With Perfect Humidity™™ Option (581B072 (6 TONS))

Cooling capacity data for 6-ton units with Perfect Humidity option.

Cooling Capacities, Units With Perfect Humidity™™ Option (581B090 (71/2 TONS))

Cooling capacity data for 7.5-ton units with Perfect Humidity option.

Cooling Capacities, Units With Perfect Humidity™™ Option (581B120 (10 TONS))

Cooling capacity data for 10-ton units with Perfect Humidity option.

Fan Performance - Vertical Discharge Units (581B036 (3 TONS) STANDARD MOTOR)

Fan performance data for 3-ton units with standard motor in vertical discharge.

Fan Performance - Vertical Discharge Units (581B048 (4 TONS) STANDARD MOTOR)

Fan performance data for 4-ton units with standard motor in vertical discharge.

Fan Performance - Vertical Discharge Units (581B060 (5 TONS) STANDARD MOTOR)

Fan performance data for 5-ton units with standard motor in vertical discharge.

Fan Performance - Vertical Discharge Units (581B072 (6 TONS) STANDARD MOTOR)

Fan performance data for 6-ton units with standard motor in vertical discharge.

Cooling Capacities (581B072 (6 TONS))

Presents cooling capacity data (TC, SHC, kW) for 6-ton units at various temperatures.

Cooling Capacities (581B102 (81/2 TONS))

Presents cooling capacity data (TC, SHC, kW) for 8.5-ton units at various temperatures.

Cooling Capacities (581B150 (121/2 TONS))

Presents cooling capacity data (TC, SHC, kW) for 12.5-ton units at various temperatures.

Cooling Capacities, Units With Perfect Humidity™™ Option (581B048 (4 TONS))

Cooling capacity data for 4-ton units with Perfect Humidity option.

Cooling Capacities, Units With Perfect Humidity™™ Option (581B102 (81/2 TONS))

Cooling capacity data for 8.5-ton units with Perfect Humidity option.

Cooling Capacities, Units With Perfect Humidity™™ Option (581B150 (121/2 TONS))

Cooling capacity data for 12.5-ton units with Perfect Humidity option.

Fan Performance - Vertical Discharge Units (581B036 (3 TONS) HIGH-STATIC MOTOR)

Fan performance data for 3-ton units with high-static motor in vertical discharge.

Fan Performance - Vertical Discharge Units (581B048 (4 TONS) HIGH-STATIC MOTOR)

Fan performance data for 4-ton units with high-static motor in vertical discharge.

Fan Performance - Vertical Discharge Units (581B060 (5 TONS) HIGH-STATIC MOTOR)

Fan performance data for 5-ton units with high-static motor in vertical discharge.

ELECTRICAL DATA

ELECTRICAL DATA (cont)

APPLICATION DATA

APPLICATION DATA (cont)

Pressure Enthalpy Curve

A pressure-enthalpy curve illustrating the refrigerant cycle with and without the Perfect Humidity package.

Perfect Humidity™ Dehumidification Package Features and Benefits

Details the advantages and features of the Perfect Humidity dehumidification package.

TYPICAL PIPING AND WIRING

TYPICAL WIRING SCHEMATIC

TYPICAL WIRING SCHEMATIC (cont)

581B036-072 Typical Wiring Schematic and Component Arrangement (208/230 V 3-Phase Unit Shown) (cont)

Continuation of the wiring schematic and component layout for a 3-phase unit.

581B090-150 Typical Wiring Schematic

Wiring schematic for larger unit sizes (581B090-150).

CONTROLS

Operating Sequence for 581B036-072 Units

Describes the operating sequences for cooling and heating modes.

CONTROLS (cont)

Operating Sequence for 581B090-150 Size Units

Describes operating sequences for larger units.

Units With Perfect Humidity™™ Dehumidification Package

Explains the operation of the Perfect Humidity package during cooling.

GUIDE SPECIFICATIONS

Part 1 - General

Covers general system description, quality assurance, and unit construction.

Part 2 - Products

Details the equipment specifications, including cabinet and fan components.

GUIDE SPECIFICATIONS (cont)

Controls and Safeties

Outlines unit controls and safety devices, including compressor protection.

Special Features

Details various optional features and accessories for the unit.