EasyManua.ls Logo

Bryant EVOLUTION 16 186B - Performance Ratings; AHRI Tested Combination Ratings

Bryant EVOLUTION 16 186B
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
TESTED AHRI COMBINATION RATINGS
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Bryant database at:
http://cactaxcredits.info/bryant-ratings/hp_ratings_srch.php
Equipment performance calculator can be accessed at: http://rpmobbry.wrightsoft.com/
Model Number Indoor Coil Model Number Furnace Mod el Number Cooling Capacity EER SEER
186BNA018****A CNPV*1917A**+TDR 18,000 12.0 14.5
186BNA024****A CNPV*3117A**+TDR 23,600 12.0 14.5
186BNA030****A CNPV*3117A**+TDR 28,600 12.0 14.5
186BNA036****A CNPV*3717A**+TDR 34,400 12.0 14.5
186BNA042****A CNPV*4324A**+TDR 41,500 12.0 14.5
186BNA048****A CNPV*6124A**+TDR 46,500 12.5 14.5
186BNA060****A CNPV*6124A**+TDR 55,000 12.5 14.5
186BNA061****A CNPV*6124A**+TDR 59,500 12.0 14.5
* AHRI = Air Conditioning, Heating & Refrigeration Institute
EER Energy Efficiency Ratio
SEER Seasonal Energy Efficiency Ratio
TDR Time---DelayRelay. Inmostcases,only1methodshouldbeusedtoachieveTDRfunction.Usingmorethan1methodinasystemmaycausedegradationinperformance.
Use either the accessory Time--- Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE
computer simulation procedures.
3. Determine actual CFM values obtainable for your s ystem by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.