16
CONDENSER ONLY RATINGS*
SST
°F(°C)
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67)
186BNA018****A
30
( --- 1.11)
TCG 14.00 13.50 13.00 12.40 11.80 11.00 10.20 9.30
SDT 65.20 74.80 84.40 94.00 103.60 113.10 122.60 132.00
KW 0.66 0.78 0.91 1.04 1.20 1.37 1.58 1.83
35
(1.67)
TCG 15.60 15.00 14.50 13.80 13.10 12.30 11.40 10.40
SDT 66.30 75.90 85.40 94.90 104.40 113.80 123.20 132.70
KW 0.65 0.77 0.90 1.04 1.20 1.38 1.58 1.83
40
(4.44)
TCG 17.30 16.70 16.10 15.30 14.60 13.70 12.70 11.70
SDT 67.50 76.90 86.40 95.80 105.20 114.60 124.00 133.30
KW 0.64 0.77 0.90 1.05 1.20 1.38 1.59 1.83
45
(7.22)
TCG 19.10 18.50 17.70 17.00 16.10 15.20 14.20 13.00
SDT 68.70 78.00 87.40 96.70 106.10 115.40 124.80 134.10
KW 0.63 0.77 0.90 1.05 1.21 1.39 1.59 1.83
50
(10.0)
TCG 21.10 20.30 19.50 18.70 17.80 16.70 15.70 14.50
SDT 69.90 79.20 88.40 97.70 107.00 116.30 125.60 134.80
KW 0.63 0.76 0.90 1.05 1.21 1.39 1.60 1.84
55
(12.78)
TCG 23.10 22.30 21.50 20.50 19.50 18.40 17.20 15.90
SDT 71.20 80.40 89.60 98.80 108.00 117.20 126.50 135.60
KW 0.62 0.76 0.91 1.06 1.22 1.40 1.61 1.85
186BNA024*A
30
( --- 1.11)
TCG 20.10 19.40 18.50 17.60 16.70 15.60 14.40 13.10
SDT 66.10 75.80 85.30 94.90 104.40 114.00 123.40 132.80
KW 0.97 1.13 1.29 1.46 1.65 1.87 2.13 2.42
35
(1.67)
TCG 22.30 21.40 20.50 19.50 18.50 17.30 16.00 14.70
SDT 67.20 76.80 86.30 95.80 105.30 114.70 124.10 133.50
KW 0.96 1.12 1.29 1.46 1.66 1.87 2.13 2.42
40
(4.44)
TCG 24.60 23.70 22.70 21.60 20.40 19.10 17.80 16.30
SDT 68.40 77.90 87.30 96.70 106.10 115.50 124.80 134.10
KW 0.95 1.12 1.29 1.46 1.66 1.88 2.13 2.42
45
(7.22)
TCG 27.10 26.00 24.90 23.70 22.40 21.10 19.60 18.00
SDT 69.60 79.00 88.30 97.60 107.00 116.30 125.60 134.90
KW 0.94 1.11 1.29 1.47 1.67 1.89 2.14 2.43
50
(10.0)
TCG 29.70 28.60 27.30 26.00 24.60 23.10 21.50 19.80
SDT 70.80 80.10 89.40 98.70 107.90 117.20 126.40 135.60
KW 0.93 1.11 1.29 1.47 1.67 1.90 2.15 2.43
55
(12.78)
TCG 32.50 31.20 29.90 28.40 26.90 25.30 23.50 21.70
SDT 72.10 81.30 90.50 99.70 108.90 118.10 127.30 136.40
KW 0.93 1.11 1.29 1.48 1.69 1.91 2.16 2.45
186BNA030000BAAA
30
( --- 1.11)
TCG 23.80 22.90 21.90 20.90 19.80 18.50 17.00 15.30
SDT 68.10 77.50 87.00 96.40 105.80 115.10 124.40 133.60
KW 1.14 1.32 1.52 1.74 1.99 2.29 2.63 3.02
35
(1.67)
TCG 26.30 25.30 24.30 23.10 21.90 20.50 19.00 17.20
SDT 69.40 78.70 88.10 97.40 106.70 116.00 125.30 134.40
KW 1.15 1.33 1.52 1.75 2.00 2.30 2.64 3.03
40
(4.44)
TCG 29.00 27.90 26.80 25.50 24.20 22.80 21.10 19.20
SDT 70.70 79.90 89.20 98.50 107.70 117.00 126.20 135.30
KW 1.16 1.33 1.53 1.75 2.01 2.31 2.65 3.05
45
(7.22)
TCG 31.90 30.70 29.40 28.10 26.70 25.10 23.40 21.40
SDT 72.00 81.20 90.40 99.60 108.80 118.00 127.20 136.30
KW 1.16 1.33 1.53 1.76 2.01 2.31 2.66 3.06
50
(10.0)
TCG 35.00 33.60 32.30 30.80 29.30 27.60 25.70 23.60
SDT 73.50 82.50 91.60 100.80 110.00 119.20 128.20 137.20
KW 1.16 1.33 1.53 1.76 2.02 2.32 2.67 3.07
55
(12.78)
TCG 38.30 36.80 35.30 33.70 32.00 30.20 28.20 26.00
SDT 75.00 84.00 93.00 102.10 111.20 120.30 129.30 138.20
KW 1.15 1.33 1.53 1.76 2.02 2.32 2.67 3.08
See notes on page 18
186B