Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-53547014-01 Printed in U.S.A. Form II547K-4-7-03 Pg 1 12-22 Replaces: II547K-4-7-02
Installation Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1
MODEL NUMBER NOMENCLATURE AND
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rated Indoor Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Jobsite Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Step 1 — Plan for Unit Location . . . . . . . . . . . . . . . . . . . . . 7
• ROOF MOUNT
Step 2 — Plan for Sequence of Unit Installation . . . . . . . . 7
• CURB-MOUNTED INSTALLATION
• PAD-MOUNTED INSTALLATION
• FRAME-MOUNTED INSTALLATION
Step 3 — Inspect Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Step 4 — Provide Unit Support . . . . . . . . . . . . . . . . . . . . . . 7
• ROOF CURB MOUNT
• SLAB MOUNT (HORIZONTAL UNITS ONLY)
• ALTERNATE UNIT SUPPORT (IN LIEU OF CURB
OR SLAB MOUNT)
Step 5 — Field Fabricate Ductwork . . . . . . . . . . . . . . . . . . 9
• FOR UNITS WITH ACCESSORY ELECTRIC
HEATERS
Step 6 — Rig and Place Unit . . . . . . . . . . . . . . . . . . . . . . . . 9
• POSITIONING ON CURB
Step 7 — Convert to Horizontal and Connect Ductwork
(when required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Step 8 — Install Outside Air Hood . . . . . . . . . . . . . . . . . . 11
• ECONOMIZER HOOD AND TWO-POSITION DAMPER
HOOD PACKAGE REMOVAL AND SETUP (FACTORY
OPTION)
• ECONOMIZER AND 2-POSITION HOOD
Step 9 — Units with Hinged Panels Only . . . . . . . . . . . . . 12
Step 10 — Install External Condensate Trap
and Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Step 11 — Make Electrical Connections . . . . . . . . . . . . . 13
• FIELD POWER SUPPLY
• UNITS WITH FACTORY-INSTALLED NON-FUSED
DISCONNECT
• UNITS WITHOUT FACTORY-INSTALLED
NON-FUSED DISCONNECT
• ALL UNITS
• CONVENIENCE OUTLETS
• FACTORY OPTION THRU-BASE CONNECTIONS
• UNITS WITHOUT THRU-BASE CONNECTIONS
• FIELD CONTROL WIRING
• THERMOSTAT
• UNIT WITHOUT THRU-BASE CONNECTION KIT
• HEAT ANTICIPATOR SETTINGS
• COMMERCIAL DEFROST CONTROL
• ELECTRIC HEATERS
• SINGLE POINT BOXES AND SUPPLEMENTARY
FUSES
• SINGLE POINT BOXES WITHOUT FUSES
• LOW-VOLTAGE CONTROL CONNECTIONS
• CONTROL AND POWER WIRING DIAGRAMS
EconoMi$er
®
X (Factory Option) . . . . . . . . . . . . . . . . . . . 28
• SYSTEM COMPONENTS
• SPECIFICATIONS
•INPUTS
•OUTPUTS
• ENVIRONMENTAL
• ECONOMIZER MODULE WIRING DETAILS
• S-BUS SENSOR WIRING
•CO
2
SENSOR WIRING
• INTERFACE OVERVIEW
• SETUP AND CONFIGURATION
• ENTHALPY SETTINGS
• TWO-SPEED FAN OPERATION
• CHECKOUT
• TROUBLESHOOTING
RTU Open Controller (Factory Option) . . . . . . . . . . . . . 42
Controller Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
• LOW AMBIENT
Smoke Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
• COMPLETING RETURN AIR SMOKE SENSOR
INSTALLATION
• ADDITIONAL APPLICATION DATA
Step 12 — Adjust Factory-Installed Options . . . . . . . . . . 42
• SMOKE DETECTORS
• ECONOMI$ER IV OCCUPANCY SWITCH
Step 13 — Install Accessories . . . . . . . . . . . . . . . . . . . . . . 42
Step 14 — Fan Speed Set Up . . . . . . . . . . . . . . . . . . . . . . . 44
• UNITS WITH ELECTROMECHANICAL CONTROLS
Typical Unit Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Pre-Start and Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . . . CL-1
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock
or other conditions which may cause personal injury or
property damage. Consult a qualified installer, service agency,
or your distributor or branch for information or assistance. The
qualified installer or agency must use factory-authorized kits or
accessories when modifying this product. Refer to the
individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses and work gloves.
Use quenching cloths for brazing operations and have a fire
extinguisher available. Read these instructions thoroughly and
follow all warnings or cautions attached to the unit. Consult
local building codes and appropriate national electrical codes
(in U.S.A., ANSI/NFPA70, National Electrical Code (NEC); in
Canada, CSA C22.1) for special requirements.
It is important to recognize safety information. This is the
safety-alert symbol . When you see this symbol on the unit
Legacy
™
Line
547K*04-07
Single Package Rooftop Heat Pump
with Puron
®
(R-410A) Refrigerant