20
A07218
Fig. 13 Cover on Equipment Control Module
14. Turn on power to equipment. On power up, all display segments will
light for 5 sec. For the next 5 sec a 2digit code appears on large display
which identifies Thermidistat Control configuration. Refer to Option 33.
a. AC 1stage air conditioner
b. HP 1stage heat pump
c. A2 2stage air conditioner
d. H2 2stage heat pump
e. hh Hybrid Heat system with 1stage heat pump
f. h2 Hybrid Heat system with 2stage heat pump
g. H heating only system
h. C cooling only system