EasyManuals Logo

Bryant T6?PRH?A User Manual

Bryant T6?PRH?A
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
66
Typical Single-Stage
Equipment Control Module Fan Coil Heat Pump
O
RVS Cooling O/B W2 E W2
Heat Stage 2 W/W1 W2
Heat Stage 3 Y1 / W2 W3
Heat/Cool Stage 1 Y/Y2 Y
Fan G G
24VAC Hot Heating Rh R R
24VAC Hot Cooling Rc
Dry Contact 1 D1
Dry Contact 2 D2
24VAC Common C C C
Humidify HUM
Outdoor Air Temp OAT
Remote Room Sensor RRS
OAT/RRS Com SRTN
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor *
* Indicates connection may not be required/available.
A09165
Fig. 20 Typical Fan Coil with Heat Pump

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant T6?PRH?A and is the answer not in the manual?

Bryant T6?PRH?A Specifications

General IconGeneral
BrandBryant
ModelT6?PRH?A
CategoryThermostat
LanguageEnglish

Related product manuals