EasyManua.ls Logo

Buck M500 - Page 28

Default Icon
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SECTION L
Standard EZScan 2 Installation
1. EZScan IR Setup cannot install system files or update files if in use. Before proceeding, we
recommend that you close any applications you may have running. You can check by seeing if
any programs are in your Programs, StartUp section. If there are, you can stop them or move
them out of StartUp. (With the Advanced section of the Taskbar menu).
2. Put the EZScan IR CD into the D:\ drive and use Browse to find and run the setup.exe file in the
ezscan2-cd sub directory. It will say, “Copying files please stand by” (If necessary it may
prompt you to restart your computer to put all the Windows\Systems changes into operation. If
this happens after the reboot, run setup.exe again.)
3. The software will remind you that no other application should be running at the same time. (This
may not be critical). Click OK to continue or Exit to leave the installation.
4. The EZScan Setup will then start. It will install the files into C:\ProgramFiles\Buck500V and
make an EZScan section under Programs. (Do not change the install directory if using Vista or
7).
5. During EZScan installation you can get the message a file being copied is older than the file
currently in place on your system. It is recommended that you keep your existing file. Ex. C:\
Windows\System\Msvcrt20.dll, or CTL3D32.dll. Do you want to keep this file? Click the Yes
button and if more files are found like this one click Yes until it is done.
6. When done the EZScan IR is completed successfully Click OK to finish. You can now remove
the CD. The buck500.ini file is in the EZScan directory if you are not connected to serial port 1.
7. Setting up the Serial Connection-
a) Plug the Buck Model 500’s null model cable (500-1135) into Serial Port 1.
Note: If Comm 1 is already being used, you can connect the instrument to Comm 2.
However, you will need to edit the buck500.ini file. Use Notepad to edit the file. Line 2
should read “Port=2” to find the M500 connected to Comm2. Remember to save the changes
before you exit Notepad. (Serial Port 3 and 4 are not supported.)
8. See EZScan Operating Instructions.
9. The Ezscan2 Software was tested with Windows 98SE, Windows 2000 and Windows XP-Pro.
All versions were English versions. There are issues with some other language versions. It does
not work correctly with the Chinese and Korean versions of Windows that our representatives
have tested. It installs but when you go to collect data you get bad command errors.
28