ELECTRICAL REQUIREMENTS
120V AC
Single phase models
Note: This electrical service re-
quires 2 current carrying conduc-
tors (Neutral, and L1) and a separate
conductor for earth ground.
Requirements for brewers without an attached cord set are as follows:
Requirements for brewers with an attached cord set are as follows:
120V
120/208-240V
For Supply Connections, Use No. 12 AWG
Wires Suitable For At Least 90oC (194oF)
FOR USE ONLY ON AN
INDIVIDUAL BRANCH
CIRCUIT RATED 20 AMPS
120V
120/208-240V
For Supply Connections, Use No. 12 AWG
Wires Suitable For At Least 90oC (194oF)
FOR USE ONLY ON AN
INDIVIDUAL BRANCH
CIRCUIT RATED 20 AMPS
Dual Voltage Switch in
120V position
Dual Voltage Switch in
120/208-240V position
120/208 & 120/240V AC
Single phase models
Note: This electrical service
require 3 current carrying
conductors (Neutral, L1 and
L2) and a separate conductor
for earth ground
Single & Dual Volt Models
N
L1
G
L2 RED L2 RED
POWER CORD
WHITE
GREEN
NEUTRAL
L1 BLACK
WHITENEUTRAL
L2
L1 BLACK
WHITE
NEUTRAL
L1 BLACK
N
L1
G
POWER CORD
GREEN
WHITENEUTRAL
L1 BLACK
L2 RED L2 RED
L2
L1 BLACK
L1
G
POWER CORD
GREEN
L1 BLACK
120/208-240V 3 WIRE + GROUND
120V 2 WIRE + GROUND
240V 2 WIRE + GROUND
L2 RED NEUTRAL BLUE
N
L1 BLACK
L1
G
POWER CORD
GREEN/YELLOW
L1 BROWN
230V 2 WIRE + GROUND
A &B Models