14
DRAINING THE DISPENSER - OHW
CAUTION - The dispenser must be disconnected from the power source throughout these steps.
1. Disconnect the dispenser from the power source and allow dispenser to cool.
2. Tilt dispenser forward over sink.
3. Open faucet.
4. Continue tilting dispenser forward over sink until water stops flowing.
NOTE - The dispenser must be full using the INITIAL SET-UP steps before reconnecting to the power source.
DRAINING THE DISPENSER - ALL 2, 5 & 10 GALLON MODELS
CAUTION - The dispenser must be disconnected from the power source throughout these steps.
1. Disconnect the dispenser from the power source.
2. Shut-off and disconnect the incoming water supply and allow dispenser to cool.
3. Remove the 4-40 screws and the top cover.
4. Gently remove one of the grommets from the tank lid.
5. Insert a tube to the bottom of the tank and syphon ALL of the water out.
CLEANING
The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all
surfaces on Bunn-O-Matic equipment.
WALL MOUNTED INSTALLATION - 5 GALLON MODELS ONLY
If the dispenser is wall mounted, the bottom of the dispenser should be at the same height as a counter or
table top. Use B.O.M. part #12542.0000 for side mounted Wall Bracket Kit or # 13125.0001 for front mounted
Wall Bracket Kit .
SUPPORT FOR LARGE RECEPTACLES
CAUTION: If the dispenser is to be used with larger receptacles such as pitchers or pots, those receptacles must
be adequately supported during dispensing of hot water to avoid spillage of very hot water. This support may be
provided by a table or counter top, or use B.O.M. part #12599.0000 Shelf Kit.
46819 043012

Other manuals for Bunn H5X