22
TROUBLESHOOTING (cont.)
Dispense station not working
All stations dispense concentrate
only
1. Dispense Lockout switch set to
OFF position.
2. Dispense switch failed
Main water supply
Frozen bath
Inlet water valve failed
Place switch in ON position.
Check switch and harness for proper
continuity.
Check for ON position.
A) Compressor relay/contacts
shorted - replace relay.
B) Recirculating pump - replace or
check for kinked flex line.
A) Check for 120V or 230V power
when dispensing. If yes, replace
valve. If no, check harness for
proper continuity. Then replace
circuit board if needed.
PROBLEM
PROBABLE CAUSE
REMEDY