47
LEAK TEST
• Use a commercially available leak detection spray or paint brush and soapy water
to check all connections (mixing ratio of soap to water 1:3).
• Open the gas cylinder valve. Bubbles will appear on all leaking points.
• Close the valve again.
• Tighten the nuts on both sides by hand again and repeat the leak test. If you still
notice bubbles, close the gas valve and consult a specialist dealer.
Repeat the leak test every time you change the gas cylinder.
3. Place the gas cylinder on a level, non-flammable surface next to the grill.
4. Screw the union nut on the gas hose onto the pressure regulator.
Use a wrench to tighten the connection.
5. Screw the union nut on the pressure regulator onto the gas cylinder.
Use your hand to tighten the connection.
Permitted gas cylinder sizes
5 kg (Max. height 480 mm, max. diameter 240 mm)
8 kg (Max. height 456 mm, max. diameter 298 mm)
11 kg (Max. height 600 mm, max. diameter 300 mm)