5 | Installation
8 / 40 0870220060_MH0018A_-0001_IM_en
5.2.1 Suction Connection
WARNING
Unprotected connection.
Risk of severe injury!
• Do not put hand or fingers in the connection.
NOTICE
Inlet gas particle size.
Risk of damage to the machine!
• Make sure that the inlet gas complies with ISO 12103-1, A.2 fine test dust.
NOTICE
Ingress of foreign objects or liquids.
Risk of damage to the machine!
If the inlet gas contains dust or other foreign solid particles:
• Install a suitable filter (5micron or less) upstream from the machine.
Connection size(s):
– G1/2
Depending on the specific order, other connection dimensions may apply.
• Make sure that the gas is drawn without obstruction.
• Provide a water separator upstream of the suction connection. Liquid water perman-
ently flowing through the process chamber will reduce its lifetime in a proportion
linked to the amount of that liquid water.
5.2.2 Discharge Connection
WARNING
Unprotected connection.
Risk of severe injury!
• Do not put hand or fingers in the connection.
Connection size(s):
– G1/2
Depending on the specific order, other connection dimensions may apply.
• Make sure that the discharged gas will flow without obstruction. Do not shut off or
throttle the discharge line.