5 | Installation
8 / 40 0870220060_MH0018A_-0001_IM_en
5.2.1 Suction Connection
WARNING
Unprotected connection.
Risk of severe injury!
Do not put hand or fingers in the connection.
NOTICE
Inlet gas particle size.
Risk of damage to the machine!
Make sure that the inlet gas complies with ISO 12103-1, A.2 fine test dust.
NOTICE
Ingress of foreign objects or liquids.
Risk of damage to the machine!
If the inlet gas contains dust or other foreign solid particles:
Install a suitable filter (5micron or less) upstream from the machine.
Connection size(s):
G1/2
Depending on the specific order, other connection dimensions may apply.
Make sure that the gas is drawn without obstruction.
Provide a water separator upstream of the suction connection. Liquid water perman-
ently flowing through the process chamber will reduce its lifetime in a proportion
linked to the amount of that liquid water.
5.2.2 Discharge Connection
WARNING
Unprotected connection.
Risk of severe injury!
Do not put hand or fingers in the connection.
Connection size(s):
G1/2
Depending on the specific order, other connection dimensions may apply.
Make sure that the discharged gas will flow without obstruction. Do not shut off or
throttle the discharge line.