or online at www.bush-support.com If you still require further assistance, call one of our experts on 0345 257 7271.
Installing your combined cooker
Installing your combined cooker
Bringing it all together
Gas pipe
Mechaniccal
gas hose
Seal
Mechanical gas
hose
Mechanical
gas hose
The Cooker must be installed and maintained by
a suitably qualified gas registered technician in
accordance with current safety legislation.
WARNING: Do not use a naked flame to check for
gas leaks.
Gas conversion (
If Available
)
Your appliance is designed to be operated with LPG/
NG gas. The gas burners can be adapted to different
types of gas, by replacing the corresponding injectors
and adjusting the minimum flame length suitable to the
gas in use. For this purpose, the following steps should
be performed.
Changing injectors
Hob burners
Cut off the main gas supply and unplug the
appliance from the mains electrical supply.
Remove the burner caps and the adapters.
Use a 7 mm spanner to unscrew the injectors.
Replace the injector with the ones from the gas
conversion kit, with the correct diameters for the
type of gas that is going to be used, according to
the gas injector table.
Adapter
Spanner
Adapter
Cup
Burner cap
Adjusting the minimum flame position
First of all, make sure that the appliance is unplugged
from the mains electrical supply and that the gas feed
is open. The minimum flame position is adjusted
with a flat screw located on the valve. For valves with
a flame failure safety device, the screw is located on
the side of the valve spindle as shown in the figures.
For valves without a flame failure safety device, the
screw is located inside the valve spindle as shown in
the figure. To make adjusting the flame position easier,
we recommend that you remove the control panel
(and the micro switch if your model has one) during
the alteration. The bypass screw must be loosened for
conversion from LPG to NG. For conversion from NG
to LPG, the bypass screw must be tightened.