2018/12 – B - Code : 33315
Nota bene: technical data and dimensions may be subject to modification, without notification, over time due to
product improvements. For more detail, refer to the information plate on the machine.
When the weather is cold and damp, frost can build up on the evaporator fins. This phenomenon is not the result of
a malfunction; the frost will be eliminated by automatic triggering of the thermodynamic defrosting cycle (inversion
of the refrigerant cycle). Once the frost has been melted, the machine will revert to normal operating mode.
The heat pump is fitted with a flow controller that only allows the machine to start up when the water flow rate
through the machine is adequate (see the recommended values in the technical data table).
V. Product installation
V.1) Siting
The following points must be taken into consideration:
The device must be installed outdoors
Condensate drainage
Connect the elbows and the condensate drainage hose to the hole in the machine floor such that the
condensates will be channeled to waste. Do not mix condensates with the pool water.
Distance from the water area
The distance must satisfy the stipulations of the local regulations if effect at the installation site. However,
this distance should not be so great that the length of the pipes makes it impossible to achieve the minimum
water flow rate necessary for correct operation of the
machine.
Clearance
The minimum recommended clearances between each
surface of the machine and the nearest obstacle (wall,
partition, hedge, etc.) are shown as indicated :
The machine should not be located in a corner where air
circulation and renewal could be hindered.