ADJUSTMENT
PROCEDURES
ccontinuea)
6.
The
waveform
appears
again
if
the
OPEN/CLOSE
button
is
pressed
again.
This
allows
for
confirmation
to
be
made.
The
pick-up
is
faulty
if
confirmation
cannot
be
made.
SETTING
OF
INITIAL
POSITION
OF
VOLUME
1.
The
variable
resistors
are
set
to
the
following
initial
positions.
P101
(E-F
BALANCE)
.................
Mechanical
center
P102
(FOCUS
OFFSET)................
Mechanical
center
P103
(TRACKING
OFFSET)
...........
Mechanical
center
P104
(TRACKING
GAIN)...............
Mechanical
center
P105
(FOCUS
GAIN)..................5.
Mechanical
center
P106
(KICK
GAIN)
..............0..00005
Mechanical
center
FREE
RUN
FRECUENCY
ADJUSTMENT
1.
Turnon
the
power
and
set
the
unit
to
the
STOP
mode.
2.
Connect
the
frequency
counter
between
test
pin
VCO
of
connector
CN8
and
test
pin
GND
(use
probes).
3.
Rotate
the
core
of
the
PLL
OSC
coil
(T102)
with
a
plastic
screwdriver
so
that
the
frequency
counter
indicates
4.3218MHz.
FOCUS
OFFSET
ADJUSTMENT
1.
Turnon
the
power
and
set
the
unit
to
the
STOP
mode.
2.
Connect
a
DC
voltmeter
and
oscilloscope
between
test
pin
F-COIL
of
connector
CN6
and
test
pin
GND.
Short
test
pin
FOFF
of
connector
CN7
and
test
pin
GND.
3.
Adjust
P102
so
that
the
indication
on
the
DC
voltmeter
and
oscilloscope
is
OV+10mvV.
4.
Remove
the
short
between
test
pin
FOFF
and
test
pin
GND.
TRACKING
OFFSET
ADJUSTMENT
1.
Turnon
the
power
and
set
the
unit
to
the
STOP
mode.
2.
Connect
a
DC
voltmeter
and
oscilloscope
between
test
point
T-COIL
of
connector
CN6
and
test
pin
GND.
Short
test
pin
TP11
and
test
pin
GND.
3.
Adjust
P103
so
that
the
indication
on
the
DC
voltmeter
and
oscilloscope
is
OV+10mV.
4.
Remove
the
short
between
test
pin
TP11
and
test
pin
GND.
NOTE:
This
adjustment
should
be
made
again
after
the
adjustment
of
Tracking
Gain.
=41—
ADJUSTMENT
OF
DIFFRACTION
GRID
This
unit
uses
a
three
beam
method
for
the
laser
pick-up.
Diffraction
grid
adjustment
involves
adjusting
the
position
of
the
E
and
F
beams
in
relation
to
the
main
beam
so
that
they
are
in
the
same
line.
The
following
is
the
adjustment
procedure.
This
is
a
precise
12
GND
adjustment
and
must
be
made
carefully.
Turn
on
the
power,
place
test
disk
YEDS4
on
the
table
load
and
set
the
unit
to
the
STOP
mode.
Short
test
pins
TP17
and
TP18
of
connector
CN6.
Short
test
pin
TROFF
(TP5)
of
connector
CN7
and
test
pin
GND.
Pass
test
pins
E
(TP3)
and
F
(TP2)
through
the
band
pass
filter,
and
connect
to
the
channels
of
the
dualtrace
oscilloscope.
The
ground
is
obtained
from
test
point
GND.
10K
0.047
Dualtrace
GND
Oscilloscope
F
——-w—Hi
Press
the
F.F
button.
The
TRACK/INDEX
indication
is
“2”
and
the
disk
begins
to
rotate.
Continue
to
press
the
PLAY/PAUSE
button.
The
unit
is
rotating
in
this
state
with
the
tracking
servo
turned
off.
Observe
the
resurge
waveform
of
the
waveform
indicated
on
the
oscilloscope
and
insert
the
adjustment
jig
into
the
diffraction
grid
holes
to
adjust
the
diffraction
grid
so
that
the
phase
difference
is
180°.