Load configuration reference
UPS(VA)=PCpowerATX(Watt)/0.6+Monitor(VA)
Monitorpower(reference)
15”CRT 15”LCD 17”CRT 17”LCD 19”CRT 19”LCD
80VA 40VA 130VA 60VA 180VA 80VA
Troubleshooting
Problem PossibleCause ActionToTake
UPSnoton&
NoLED’son
i.BatteryDischarged.Sleep
Mode.
PressthePOWERbuttonON
ii.PCBfailure ContactServiceAgent
UPSalwaysatbattery
mode
Powercordlose Replugthepowercord
Linevoltagetoohigh,too
loworblackout
Normalcondition
PCBfailure ContactServiceAgent
sBuzzercontinuously
sounding
i.ShortCircuit. Removethenoncriticalloads
ii.UPSFaulty ContactServiceAgent
UPSdoesnotprovide
expectedruntime.Low
batterywarningis
soundedprematurely.
Batteryisweakduetowear
orsuccessivemains
outages.
AllowUPStorechargebattery
foraminimumof8hours.IfUPS
soundslowbatterywarning
prematurely,whenretested,
batteryshouldbereplaced.