Load configuration reference
UPS(VA)=PCpowerATX(Watt)/0.6+Monitor(VA)
Monitorpower(reference)
15”CRT 15”LCD 17”CRT 17”LCD 19”CRT 19”LCD
80VA 40VA 130VA 60VA 180VA 80VA
21 of 21
Troubleshooting
Problem PossibleCause ActionToTake
UPSnoton&
NoLED’son
i.BatteryDischarged.Sleep
Mode.
PressthePOWERbuttonON
ii.PCBfailure ContactServiceAgent
UPSalwaysatbattery
mode
Powercordlose Replugthepowercord
Linevoltagetoohigh,too
loworblackout
Normalcondition
PCBfailure ContactServiceAgent
sBuzzercontinuously
sounding
i.ShortCircuit. Removethenoncriticalloads
ii.UPSFaulty ContactServiceAgent
UPSdoesnotprovide
expectedruntime.Low
batterywarningis
soundedprematurely.
Batteryisweakduetowear
orsuccessivemains
outages.
AllowUPStorechargebattery
foraminimumof8hours.IfUPS
soundslowbatterywarning
prematurely,whenretested,
batteryshouldbereplaced.