EasyManua.ls Logo

Cadet EP101T - User Manual

Default Icon
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
cadetheat.com Tel: 855.CADETUS PO Box 1675 Vancouver, WA 98668-1675
%HQH¿WV<RX&DQ'HSHQG2Q
SAVE THESE INSTRUCTIONS
Energy Plus Heater
Owners Guide
F
NO
NO
HEAT
FAN
ONLY
SLEEP
HEAT
+
5
/
8
1.6cm
9”
22.9cm
Side Grill Front Wall Can Side
Wall Can Bottom
12”
30.5cm
10”
25.4cm
11
1
/
8
28.3cm
3¼”
8.3cm
1¼”
3.2cm
1¾”
4.5cm
1¼”
3.2cm
3”
7.6cm
4”
10.2cm
7
7
/
8
20.0cm
F
NO
NO
HEAT
Model:
Volts:
Watts:
WARNING! TO AVOID ELECTRICAL SHOCK
Disconnect power at circuit breaker before servicing.
Do not operate without grill.
cadetheat.com
Vancouver, WA
Mfg Date:
Before pushing
RESET button see
Owner’s Guide
for display fault
codes and other
troubleshooting
information.
3108579
conforms
to UL STD
2021
072xxx
TOOLS REQUIRED:
• Phillips Screwdriver
• Straight Screwdriver
• Wire Strippers
• Utility Knife
• (4) 1½" Wood Screws
• (2) Insulated Wire Connectors
• (1) Strain Relief Connector
6HQVLEOHDQGHQHUJ\HI¿FLHQWXVHXSWROHVV
energy
%ULQJV\RXRQO\WKHKHDW\RXQHHGZKHQ\RXQHHGLW
and adjusts automatically to save you money
<RXGH¿QH\RXUFRPIRUW²PDLQWDLQV\RXUURRPWHP-
perature within one degree
Our most thoughtful design features:
Large digital display shows your room temperature
and heating mode
(DV\LQWXLWLYHRQHWRXFKFRQWUROV
Night/Away option for extra savings
,PSURYHDLUFLUFXODWLRQDGGFRPIRUWLQRIIVHDVRQ
with three fan speeds
,QVWDOOVLQHDV\VWHSV
Common sense components designed with you in
mind:
Peace of mind safety with automatic high
temperature shutoff
No sharp edges
Corrosion resistant
Our sturdiest element provides comfortable warmth
for years of reliable use
Your Energy Plus heater has been thoroughly tested
and is guaranteed with a \HDUH[WHQGHGZDUUDQW\
(QHUJ\3OXV0RGHOV
/LQH
9ROWDJH
0RGHO :DWWV $PSV
120 (37 1000 8.3
http://www.cadetheat.com/products/wall-heaters/energy-plus
Information is also available on our website:
Page 1
Energy Plus Model With Built-In Controller
:DOO7KHUPRVWDW1RW5HTXLUHG
Controller with Digital Display
and Push Buttons
Rating Label
PATENT PENDING
Conforms to UL Std.
DQG&HUWL¿HGWR
CAN/CSA Std. C22.2
No. 46
COM-PAK


Questions and Answers

  • S
    Steven HendricksAug 12, 2025
    What to do if my Cadet EP101T Heater is working but the room is not warm enough?
    • N
      Nancy RoseAug 12, 2025
      If your Cadet Heater is running but the room isn't reaching the desired temperature, it could be due to: * Heat loss: Ensure doors and windows are closed to minimize heat loss. * Insufficient insulation: Add more insulation or consider using a higher wattage heater or multiple heaters, provided your circuit has the capacity. * Obstructed airflow: Make sure furniture or other items aren't blocking the heater, allowing air to flow freely. Keep a minimum distance of 18 inches from nearby surfaces.
  • D
    dpowellAug 16, 2025
    What to do if my Cadet Heater will not shut off?
    • P
      Paige HancockAug 16, 2025
      If your Cadet Heater will not shut off, consider the following possibilities: * Normal operation: If the room temperature is being regulated, a low fan speed and low heat output are normal for this energy-saving heater. * Heat loss: Ensure doors and windows are closed to prevent heat loss. * Insufficient insulation: Add more insulation or install a higher wattage heater or multiple heaters if necessary, provided your circuit has the capacity. * Faulty heater assembly: Replace the heater assembly.
  • J
    justin18Aug 19, 2025
    Why is my Cadet Heater fan running but not blowing warm air?
    • E
      Emily SmithAug 20, 2025
      If the fan in your Cadet Heater is running, but it's not discharging warm air, here are a couple of potential causes: * The rocker switch isn't in HEAT mode: Push the rocker switch to the HEAT mode. * The element has failed: Replace the element.
  • B
    Benjamin LeonAug 23, 2025
    How to troubleshoot a Cadet EP101T that doesn't run?
    • M
      Mrs. Kelly BallardAug 25, 2025
      If your Cadet Heater isn't running, try these steps: * Check the thermostat: Adjust the thermostat to a higher temperature until the heater operates. If the problem persists, see Problem #6. * Check the circuit breaker: Turn on the correct circuit breaker in the main disconnect panel. * Check the wiring: Check the supply wire continuity and proper connection to heater wires. * Repair or replace the heater assembly. * Correct the circuit breaker installation.
  • J
    Jessica FrancisAug 27, 2025
    Why does my Cadet EP101T trip the breaker immediately?
    • B
      Bobby VazquezAug 27, 2025
      Your Cadet Heater might be tripping the breaker due to several reasons: * An overloaded circuit: The total amperage of all heaters on a branch circuit must not be more than the amperage rating of the circuit breaker and supply wire ratings. Use a lower wattage heater or reduce the number of heaters on the circuit. * A short circuit: Inspect all supply and heater wiring insulation for damage. Do not reset the circuit breaker until all electrical shorts have been repaired. * A faulty circuit breaker: Replace the circuit breaker. * A faulty heater assembly: Replace heater assembly.
  • H
    hinesjudyAug 30, 2025
    Why does my Cadet EP101T discharge smoke or emit a burnt odor?
    • M
      melissa88Aug 31, 2025
      If your Cadet Heater discharges smoke or emits a burnt odor, it could be caused by: * Accumulated dust, lint, or other matter inside the heater: Clean the heater. See the "MAINTAINING YOUR HEATER" section for instructions. * Poor or loose electrical connections: Turn off the power at the circuit breaker and inspect all supply and heater wires for loose or poor connections. Secure or reconnect any loose connections. Do not reset the circuit breaker until all connections have been checked and repaired.
  • P
    paullewisSep 3, 2025
    What to do if my Cadet Heater keeps tripping the manual reset temperature limit control?
    • R
      Rebecca RomanSep 3, 2025
      If your Cadet Heater continually trips the manual reset temperature limit control, the following could be the cause: * Accumulated dust, lint, or other matter inside the heater: Clean the heater. Refer to the "MAINTAINING YOUR HEATER" section for instructions. * Blocked airflow: The fan or motor might be jammed. Remove any obstruction. * Faulty heater assembly: Replace the heater assembly.
  • J
    John McculloughSep 7, 2025
    What to do if my Cadet EP101T Heater element heats for a moment then immediately stops?
    • M
      Michele RangelSep 7, 2025
      If the element in your Cadet Heater heats briefly and then stops, it could be due to: * A defective motor or internal connection: The heater or fan motor may need replacement. * A jammed fan: Remove any obstruction and ensure the fan spins freely.

Summary

Benefits of the Energy Plus Heater

Energy Efficiency and Comfort

Uses up to 30% less energy, maintains precise room temperature and adjusts automatically.

Important Safety Instructions

General Safety Precautions

Follow precautions for fire, shock, and injury, keep combustibles away, avoid bare skin contact.

Electrical Shock and Fire Hazards

Includes warnings about operating after malfunction, foreign objects, and operating without a grill.

Installation Instructions - Part One

Installation Instructions - Part Two

Confirming Proper Installation

Checks for correct voltage and displays status after power-up, indicating successful installation.

Operating Instructions

Temperature Control Modes

Covers setting desired room temperature and programming energy-saving night/away modes.

Troubleshooting and Maintenance

Maintaining Your Heater

Troubleshooting Common Issues

Provides solutions for common symptoms like room not reaching temperature or breaker tripping.