EasyManua.ls Logo

Cadet softHEAT EBHN500-1 - User Manual

Cadet softHEAT EBHN500-1
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
cadetheat.com Tel: 360-693-2505 PO Box 1675 Vancouver, WA 98668-1675
Benets You Can Depend On
SAVE THESE INSTRUCTIONS
softHEAT Baseboard Heater
Owners Guide
9½”
24.1cm
3¼”
8.3 cm
Side
Front
TOOLS REQUIRED:
Phillips Screwdriver
Straight Screwdriver
Wire Strippers
Drill or Hammer
Level
Punch or Chisel
Drill Bits
Utility Knife
(4) Wood Screws
(3) Wire Connectors
(1) Strain Relief Connector
Ideal for nurseries and bedrooms
Reduces airborne allergen effects
Hydronic heat uses environmentally friendly
uid for easy installation, with no plumbing
required
Saves energy by retaining heat to generate
residual warmth, even after thermostat
turns off
Lowest surface temperatures available
make it perfect for homes with kids and
pets
Whisper-quiet operation
Safety features turn heater off if normal
operating temperatures are exceeded
Your softHEAT baseboard heater has been
thoroughly tested and is guaranteed with a
7 year limited warranty
softHEAT Models
Line
Voltage
Model Watts Amps
120
EBHN500-1 500 4.2
EBHN750-1 750 6.3
EBHN1000-1 1000 8.3
EBHN1250-1 1250 10.4
EBHN1500-1 1500 12.5
208
EBHN500-8 500 2.4
EBHN750-8 750 3.6
EBHN1000-8 1000 4.8
EBHN1250-8 1250 6.0
EBHN1500-8 1500 7.2
240
(1)
EBHN500 500 2.1
EBHN750 750 3.1
EBHN1000 1000 4.2
EBHN1250 1250 5.2
EBHN1500 1500 6.3
(1)
240 volt models can be used at 208 volts. Wattage equals 75% of 240v rated
wattage.
Left end wiring is standard. Right end wiring available by special order.
Conforms to UL
STD 1042 and
certied to CSA STD
C22.2 No. 46-13
Page 1

Questions and Answers

  • K
    kcarterAug 10, 2025
    Why is my Cadet Heater not working?
    • B
      Brandy CarterAug 11, 2025
      If your Cadet Heater isn't working, it might not be getting the right voltage. First, make sure the circuit breaker is correctly positioned. Then, check the voltage at the heater between the supply wires to be sure it matches what the heater needs. Also, incorrect wiring could be the issue. Double-check that the wires are properly and securely connected using the correct wire connectors, referring to the Owner’s Guide. If it still doesn't work, an electrician with an ohmmeter should perform further testing.
  • D
    Daniel BrownAug 16, 2025
    What to do if my Cadet softHEAT EBHN500-1 will not shut off?
    • A
      Amy WilliamsAug 17, 2025
      If your Cadet Heater won't shut off, there are several potential causes. First, the room may be losing heat faster than the heater can compensate; try closing doors and windows, adding more insulation, or using a higher-wattage heater. A defective thermostat could also be the problem; turn the thermostat to its lowest setting and wait two minutes to see if the heater responds. If it doesn't, the thermostat likely needs to be replaced. Finally, the thermostat might be wired incorrectly; refer to the thermostat documentation to correct the wiring.
  • N
    nicolaschavezAug 22, 2025
    Why doesn't my Cadet softHEAT EBHN500-1 heat the room quickly?
    • K
      Katrina SweeneyAug 22, 2025
      If your Cadet Heater isn't heating the room quickly, it might be due to a slow initial warm-up, which typically takes 30 to 60 minutes. Also, check the voltage at the heater between supply wires and make sure it matches required heater voltage.
  • C
    christianalexisAug 28, 2025
    How to fix a gurgling Cadet softHEAT EBHN500-1?
    • J
      Jessica CampbellAug 28, 2025
      A gurgling noise in your Cadet Heater might mean the unit isn't level. Check to ensure it is level. If the gurgling continues for more than 30 minutes, the unit may need replacement. It could also indicate a leak, in which case you should replace the element or the entire heater.
  • D
    David WhiteSep 4, 2025
    What to do if I find liquid around my Cadet softHEAT EBHN500-1?
    • R
      Ricky BowmanSep 4, 2025
      If you find liquid in or around your Cadet Heater, it could be heat transfer fluid escaping from the element. If this occurs, stop using the heater immediately and replace the element or the entire heater, as the elements cannot be repaired.