Any GigaSpire BLAST incorporating a UPS (Sold Separately)
Connectorized Power and Signal Cable - An 8-pin (GigaCenter end) to 8-pin terminal
block (UPS end) cable available in 3 foot (1 meter) or 10 foot (3 meters) lengths.
Connectorized Power and Signal Cable - An 8-pin (GigaCenter end) to dressed and
tinned (un-terminated) cable available in 20 foot (6 meter) length.
WARNING! High voltage electrical and pressurized natural gas lines may be
present. Make sure you fully understand the locations of these and all other utility
connections before drilling through any surface.
CAUTION! The UPS is designed for indoor installation and must be installed in a
location with adequate airflow.
Make sure the UPS is not installed under water pipes which may leak or drip from
condensation.
1. Unpack the UPS and associated hardware from the carton.
2. Find a suitable location for the UPS and prepare mounting screws per the mounting hole
pattern shown below.
3. Pre-drill mounting holes (to accept an 8-32 pan head screw - not provided) of the
appropriate size.
REFERENCE: The UPS must be located less than 50 feet (15.2 meters) from the
GigaSpire when using an 18 AWG Type I power cord or less than 70 feet (21.3 meters) from
the GigaSpire when using 16 AWG Type II power cord.
8.25 inches
7.125 inches
Important: Make sure the material you are mounting the UPS to is of sufficient strength
to support its weight of 7.16 pounds (3.25 kgs).