® SECTION 5: WEATHER
making
since 1986
ater work
amount of rain from this setting put into the rain
table, will increase only until it reaches the 24
HOUR TOTAL setting.
• Maximum 24 Hour Total: This setting
determines the maximum amount of rain that will
be put into the rain table in a 24 hour period. In
figure 5.10, a maximum of (0.60) inches of rain
will be put into the table, no matter how much
rain falls in a 24 hour period. The amount of rain
from this setting put into the rain table, will
increase only until it reaches the LET RAIN
ONLY BUILD UP TO :setting.
• Let Rain Only Build Up to: This setting
determines the maximum amount of rain that will
be stored in the rain table. In figure 5.10, the
controller will stop storing rain data in the rain
table if the Maximum 24 Hour Total reaches
1.50 inches of rain.
2. Press the PLUS or MINUS keys to
change the settings.
3.
Press the blue ARROW key to
move the cursor to the next entry.
• Set Use of Rain by Program: This
section describes how to enable the use
of rain in the ET2000e controller. Each
program can be set individually to either
use or not use rain to offset irrigation run
times.
From the RAIN BUCKET SETUP screen
(Figure 5.10):
4.
Press the SET USE OF RAIN BY
PROGRAM Menu key.
The USE OF RAIN BY PROGRAM screen is
displayed (Figure 5.11
).
PROG A . . . . . . . . . . . . . . . . . . . . YES
Rain causes negative hold-over to build
USE OF RAIN BY PROGRAM
which acts to cancel irrigation.
DRIP 2 . . . . . . . . . . . . . . . . . . . . YES
Allow RAIN on the following:
PROG B . . . . . . . . . . . . . . . . . . . . YES
PROG C . . . . . . . . . . . . . . . . . . . . YES
PROG D . . . . . . . . . . . . . . . . . . . . YES
PROG E . . . . . . . . . . . . . . . . . . . . YES
DRIP 1 . . . . . . . . . . . . . . . . . . . . YES
Figure 5.11
You have the option of enabling or disabling the use
of rain (negative hold over) for any of the controller’s
seven programs. If you select YES, rain (negative
hold over) will be used for that program to reduce
irrigation run times. If you select NO, rain will have
no effect on irrigation run times for that program.
If there is no rain bucket installed and you are not
sharing rain data through the Calsense Command
CENTER program, these settings will have no effect
on irrigation.
Note:
Negative Hold-over is time subtracted from
station run times. This is caused when user set rain
parameters are crossed.
5.
Press the PLUS or MINUS keys to
change the setting.
6.
Press the blue ARROW keys to
move the cursor to the next entry.
7.
Press the MAIN MENU key to return
to the MAIN MENU screen
(Figure 5.1).
THIS CONCLUDES RAIN SETUP WITH RAIN
BUCKET INSTALLED
5B.2 Rain setup ( without Rain Bucket
installed ) and you are sharing rain to
controller.
From the WEATHER SETUP screen (Figure 5.2):
1.
Press the RAIN BUCKET Menu key.
The RAIN BUCKET SETUP screen is displayed
(Figure 5.12).
Let Rain Build up to 1.50 inches
have a -RB interface.
Rain Bucket controllers have 3 more
RAIN BUCKET SETUP
settings. This controller does not
Set Use of Rain by Program
Figure 5.12