(ENCLOSURE 1) MAXIMUM & MINIMUM SETTINGS WITHIN ET2000e ®
making
since 1986
w
ater work
MAXIMUM & MINIMUM SETTING WITHIN THE ET2000e
Maximum and Minimum settings within the ET2000e
Area Setting Minimum Maximum
Total Minutes 0.0 Minutes 999.0 Minutes
Minutes Per Cycle 1 Minutes 255 Minutes
Soak In Time 5 Minutes 1275 Minutes
No Water Days 0 Days 31 Days
Expected Flow 1 Gallons 4000 Gallons
Area Sq / Ft 100 Sq/Ft 65000 Sq/Ft
Max Days 0 Days 31 Days
Moist Set 01 99
Station Programming
% of ET 0 Percent 999 Percent
Adjust all Stations -99 Percent +200 Percent
Percent Adjust
Adjust By Program -99 Percent +200 Percent
Program Priorities Level Low High
MLB During Irrigation 1 Gallons 4000 Gallons
MLB All Other Times 1 Gallons 4000 Gallons
MLB During Use GPM 1 Gallons 4000 Gallons
MLB Not During Use GPM 1 Gallons 4000 Gallons
Schedule use for duration 1 Minute 72 Hours
Master Valve
Use Master Valve for hours 0.1 Hours 24.0 Hours
Flow Meter K Factor 0.000 Value 800.000 Value
Flow Meter
Flow Meter Offset 0.0 Value 0.200 Value
Capacity With Pump 1 Gallons 4000 Gallons
System Capacity
Capacity Without Pump 1 Gallons 4000 Gallons
From Limit 10 Gallons 4000 Gallons
To Limit 10 Gallons 4000 Gallons
Allowable limit Below -2 / +2 Gallons -200 / +200 Gallons
From / to -2 / +2 Gallons -200 / +200 Gallons
From / to -2 / +2 Gallons -200 / +200 Gallons
Flow Checking
Above -2 / +2 Gallons -200 / +200Gallons
Within Program
1-4 valves, X (based on system
capacity and electrical limit)
1-4 valves, X (based on system
capacity and electrical limit)
On-At-A-Time
Within Controller / System
1-4 valves, X (based on system
capacity and electrical limit)
1-4 valves, X (based on system
capacity and electrical limit)
Line Fill Line Fill time 30 Seconds 1800 Seconds
Valve Close Valve Close time 30 Seconds 1800 Seconds
Irrigation Day is from
5:00 PM to
5:00 PM
8:00 PM to 8:00 PM
Gage is full % 9 Percent 99 Percent
ET Gage
Gage = inches .00 Inches .30 Inches
Stop Irrigation After Inches 0.01 Inches 2.00 Inches
Maximum Rain in ONE Hour is 0.01 inches 2.00 inches
Maximum Rain in 24 Hours is inches 0.01 Inches 6.00 Inches
Rain Bucket
Let Rain Only Build up to inches 0.01 Inches 6.00 Inches
Pause Irrigation MPH 11 Miles per Hour 99 Miles per Hour
Wind Gage
Resume Irrigation MPH 1 Miles per Hour 10 Miles per Hour
ET Allowable % of Historical ET 10 Percent 300 Percent
ET State / County / City Monthly Percentage 0.00 Percent 20.00 Percent
Calculate budgets at % of ET 10 Percent 300 Percent
Yearly budget is gallons 0 Gallons 108,000,000 gallons
Budgets
Monthly gallons 0 Gallons 9,000,000 Gallons
Hold-Over Hold-Over Minutes -120.0 Minutes 120.0 Minutes
Manual Water Station Manual Water Station 0.0 Minutes 999.9 Minutes
Test Test Station 0.1 Minutes 20.0 Minutes
Station Minutes 0 Minutes 99 Minutes
Manual Program 1 &2
Run Until 1 Days 999 Days
Start your Walk-Thru in 5 Seconds 15 Minutes
Walk-Thru
Run each station for minutes 0.1 Minutes 15.0 Minutes