Anchoring the turnstile to the ground
Position the base onto the anchoring point and level
it, if necessary, using the adjusting grub screws.
Fit the slide ring and central column onto the base.
Before fastening the turnstile to the ground, lay the
cable inside the central column (see drawing).
Note: apply the ferrite to the command / accessories
cables
Fasten column
and base to the
floor using suitable
screws, slide rings
and UNI6593 M8
washers.
Connect the 230 V AC power
mains to the terminal in the
central column.
Ref. Description
Neutral
line
Ground
230 V AC transformer (red
cable)
120 V AC transformer
(black cable)
Power-supply cable
230V AC MAINS POWER SUPPLY
(Factory configuration)
120V AC MAINS POWER SUPPLY
(Invert cables 1 and 2 as shown)
Ferrite