Questions and Answers

  • A
    Amanda NelsonAug 5, 2025
    How to fix a Cameron WKM MA valve leaking around the stem?
    • B
      Brian AndradeAug 5, 2025
      If the Cameron Control Unit valve is leaking around the stem, the gland nuts may be loose, in which case you should tighten them. Alternatively, the packing may be damaged or worn, requiring you to replace the packing.
  • J
    joseph71Aug 10, 2025
    Why my Cameron Control Unit valve will not seal properly?
    • J
      Janet ScottAug 10, 2025
      If the Cameron Control Unit valve doesn't seal properly, it could be due to several reasons. The seat and/or disc might be worn or damaged, requiring replacement of the worn parts. There might be foreign matter between the seat and disc; try operating the valve several times to wipe it clean. Also, the operator stops may not be set correctly, so adjust the stops to the proper setting.
  • A
    Ann BridgesAug 14, 2025
    What to do if Cameron WKM MA valve is hard to operate?
    • E
      Erika WardAug 14, 2025
      If the Cameron Control Unit valve is hard to operate, it could be due to a buildup of solids or roughness on the edge of the disc. Try operating it several times to wipe it clean, or disassemble the valve and clean the disc edge. Another cause might be that the stem packing is too tight; tighten the packing only enough to stop leaks. Finally, the operator might not be installed properly; reinstall the operator in proper alignment with the valve stem.
  • D
    danielgillespieAug 20, 2025
    Why is my Cameron WKM MA Control Unit valve leaking between body and seat retainer?
    • Y
      Yvonne MorrisAug 20, 2025
      If the Cameron Control Unit valve leaks between the body and seat retainer, it could be that the seat retainer screws are not tight; tighten them. Another possibility is that the body gasket is damaged (FO and MO seats only), requiring you to replace the body gasket. Lastly, the seat itself might be damaged, so replace the seat.
  • J
    Jennifer GrantAug 25, 2025
    What to do if Cameron WKM MA Control Unit valve will not open?
    • A
      Anthony EdwardsAug 25, 2025
      If the Cameron Control Unit valve will not open, the disc might be hitting the side of the pipe. Check for proper pipe clearance.
  • J
    Jacob ToddAug 29, 2025
    Why Cameron WKM MA valve opens and closes with line flow?
    • B
      Brad HendersonAug 29, 2025
      If the Cameron Control Unit valve opens and closes with line flow, the handle or actuator may not provide proper restraint. Restrain the handle or actuator when in a static position.

Summary

Bill of Materials

Catalog Number Information

Nameplate Information

Details of standard and P.E.D. compliant nameplates for valve identification.

Installation

Flow Direction

Recommended positions for seat upstream or downstream based on application requirements.

Stem Position

Guidance on optimal stem orientation for various operating conditions and media.

End-of-Line Service

Disc;Pipe Clearance

Gaskets

Flange Bolts

Procedure

Valve Installation Steps

Details on valve installation steps, including gasket placement and bolt tightening.

Operation

Manually Operated

Describes manual valve operation using handle, stop plate, and stem indicators.

Worm Gear Operated

Explains operation of worm gear operators, including handwheel rotation and indicators.

Routine Maintenance

Troubleshooting