TOV
Installation, Operation and Maintenance Manual 1 WKM-TOV-IOM
Installation, Operation and Maintenance Manual
3”-24” 150/300/600 CLASS
WKM
®
- TRIPLE OFFSET VALVE
WKM
®

Questions and Answers

  • L
    Lisa CampbellAug 3, 2025
    How to fix a Cameron Control Unit valve that does not seal properly?
    • J
      Jonathan DixonAug 3, 2025
      If your Cameron Control Unit valve isn't sealing correctly, several factors could be at play. First, ensure the valve is fully closed. If that's not the issue, there might be foreign matter obstructing the seal between the seat and disc; try operating the valve a few times to clear it. Also, check if the operator stops are properly set and adjust them if necessary. If the seat or disc is worn or damaged, replacement of the worn parts is required. Lastly, verify that the seat retainer screws are tightened to the correct torque specification.
  • T
    Tracy DeckerAug 9, 2025
    Why is my Cameron WKM Control Unit valve leaking around the stem, and how can I fix it?
    • C
      clayton60Aug 9, 2025
      If your Cameron Control Unit valve is leaking around the stem, the cause may be that the packing retainer flange nuts are too loose; try tightening the packing nuts. Alternatively, the packing may be damaged, in which case you will need to replace the packing.
  • W
    walterkelliAug 15, 2025
    What to do if Cameron WKM Control Unit valve is hard to rotate?
    • C
      Cindy HaleyAug 15, 2025
      If your Cameron Control Unit valve is hard to rotate, several issues could be the cause. The shaft packing might be too tight, in that case, tighten the packing only enough to stop any leaks. The operator might have failed or not been installed correctly, consider replacing or repairing it. A build-up of solids or roughness on the disc edge could be the problem; try operating the valve several times to wipe it clean, or disassemble the valve and clean the disc edge. If the shaft key has sheared, determine the cause of the shearing and replace the shaft key correctly. Finally, fluid solidification between the bearings and shaft could be the issue; try flushing the bearings.
  • T
    Thomas LynchAug 21, 2025
    What causes jerky operation in a Cameron WKM Control Unit and how to resolve it?
    • H
      Holly LewisAug 21, 2025
      If you're experiencing jerky operation with your Cameron Control Unit, it could be due to a few reasons. The packing might be too tight, so loosen the packing nuts, cycle the valve, and then retighten them. Another possibility is an inadequate air supply for the actuator, in which case you should increase the air supply pressure and/or volume. Lastly, the actuator/shaft adapter might be misaligned; remove the actuator mounting and realign it.
  • R
    Robert RobertsonAug 27, 2025
    What to do if the bottom cap gasket is leaking on my Cameron WKM?
    • D
      Daniel ChristianAug 28, 2025
      If the bottom cap gasket on your Cameron Control Unit is leaking, it could be due to loose bottom cap bolting; try tightening the bottom cap bolting. Alternatively, the spiral wound gasket may be damaged and needs replacement.

Summary

List of Components

Catalog Number Information

Nameplate Information

Installation

Flow Direction

Specifies correct valve installation direction for optimal sealing performance.

Shaft Position

Discusses optimal orientation of the valve shaft for installation.

Disc;Pipe Clearance

Disc Protrusion Length Inside Pipe

Procedure

Worm Gear Operated

Details operation of the valve's worm gear for manual actuation.

Bolt and Stud Lengths for Installation (ASME B16.5)

ISO 5752 Flanged Body Style

Bolt and Stud Lengths for Installation (ASME B16.5)

Provides recommended bolt and stud lengths for ISO 5752 flanged body valves.

Valve Position Verification

Routine Maintenance

Troubleshooting Guide

Packing Maintenance

Sealing Elements Maintenance

Gearbox Adjustments

Close Stop Adjustment

Procedure for adjusting the close stop on the gearbox.

Open Stop Adjustment

Procedure for adjusting the open stop on the gearbox.

Bottom Cap Gasket Maintenance

Mounting Operators

Torque Charts

Chart A - Torque Table (Fasteners)

Torque values for retainer, bottom cap, and center key bolts.

Chart B - Torque Table (Packing Nuts)

Torque values for packing nuts.