Operation and maintenance instructions
Series PME proportional pressure regulator
5000044242
Ver. 01
15
7. Electrical/Pneumatic circuit
8. Product storage and transport
Adopt all measures possible to avoid accidental damage to the product during transport, and
when available use the original packaging.
Observe the specified storage temperature range of -20 ÷ 70 °C.
9. Installation and start-up
During unpacking, take great care not to damage the product.
Check whether there are any faults caused by product transport or storage.
Separate all packaging material to enable the recovery or disposal in accordance with current
standards in the country of use.
Where possible avoid the risk of repeated pressure surges on the circuit where the
component is installed.
The components must be fixed correctly using, where possible, the specific anchors and
ensuring that the fixture remains efficient even when the actuator is repeatedly used at a
high frequency and in the presence of strong vibrations.
Once the component is installed, ensure that all air ways are securely connected to the
respective couplings.
If the power supply is turned off, residual pressure may remain on the secondary side of the
regulators. The manufacturer must provide for additional exhaust components.
Recommended pneumatic circuit
Keep the protective cap of the M12 connector until the regulator is completely installed.