Operation and maintenance instructions
Series PME proportional pressure regulator
5000044242
Ver. 01
24
11.2.4. PASSWORD
By pressing the "Set new password" button you can enter a new password (up to 4 alphanumeric
characters) which will be saved in the device memory. If you forget the customized password, it will
no longer be possible to modify the regulator parameters (in this case, contact the Camozzi Service
to reset the regulator password to the factory settings). The password is not required to view the
parameters.
11.2.5. SAVING PARAMETERS
All modified parameters (including the password) are saved in the regulator memory by pressing
the “Write new parameters” button. The procedure requires entering the regulator password. The
factory password is “0000”.
12. Use
Ensure that the pressure in the compressed air supply system and all other operating
conditions remain within the admissible values.
Use with liquids or gas is not permitted according to the intended use
The LED bar on the regulator provides information regarding the status of the product,
please refer to the table below.
STATUS
MEANING
Green Fixed
Regulator is working with no errors or warnings.
Red Blinking
The regulator has registered an ERROR. Pressure regulation is interrupted.
1 flash
ALARM_INTERNAL: an internal component of regulator don’t work properly.
2 flashs
ALARM_PRESSURE: il regolatore non è riuscito a raggiungere la pressione target.
Yellow/Orange
Blinking
The regulator has registered a WARNING. Pressure regulation is not interrupted.
1 flash
WARNING_INTERNAL: an internal component of regulator don’t work properly
2 flashs
WARNING _PRESSURE: The regulator is not able to reach the target pressure.
3 flashs
WARNING_ANALOG_SIGNAL: The analog target signal is out of range..
4 flashs
WARNING_UNDERVOLTAGE: Power supply is below the minimum value
LED
STATUS
MEANING
Diagnostic
Green
Regulator is working with no errors or warnings.
Red
The regulator has registered an ERROR. Pressure
regulation is INTERRUPTED.
Yellow/Orange
The regulator has registered a WARNING. Pressure
regulation is not interrupted.
Wireless
Blu fixed
Wireless board is available and the regulator is
connected to the supervisor software UVIX
Blu blinking 1Hz
Wireless board is available but the regulator is not
connected to the supervisor software UVIX
Off
Wireless board is not available
LED
STATUS
MEANING
Diagnostic
Green
Regulator is working with no errors or warnings.
Red
The regulator has registered an ERROR. Pressure
regulation is INTERRUPTED.
Yellow/Orange
The regulator has registered a WARNING. Pressure
regulation is not interrupted.
Wireless
Blu fixed
Wireless board is available and the regulator is
connected to the supervisor software UVIX
Blu blinking 1Hz
Wireless board is available but the regulator is not
connected to the supervisor software UVIX
Off
Wireless board is not available