EasyManua.ls Logo

Camozzi PME Series - Page 18

Camozzi PME Series
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation and maintenance instructions
Series PME proportional pressure regulator
5000044242
Ver. 01
18
For the electrical connection the following cable types are available:
CODE
DESCRIPTION
CS-LF05HB-D200
co-moulded connector M12 5 pole, female, straight with 2-metre cable shielded
CS-LF05HB-D500
co-moulded connector M12 5 pole, female, straight with 5-metre cable shielded
CS-LR05HB-D200
co-moulded connector M12 5 pole, female, bend with 2-metre cable shielded
CS-LR05HB-D500
co-moulded connector M12 5 pole, female, bend with 5-metre cable shielded
CS-LR03HB-C200
co-moulded connector M12 5 pole 3 wires, female, bend with 2-metre cable unshielded
CS-LR03HB-C500
co-moulded connector M12 5 pole 3 wires, female, bend with 5-metre cable unshielded
NOTE: in the cable versions with 3 wires, only pins 1 (24 VDC), 4 (GND) and 3 (IN +) are available.
Pin 5 (Dout) is not available.
PIN
ANALOG
1
24 VDC
Power supply
Connect to the positive pole (24VDC) and to the negative pole (GND) of the power supply
4
GND
3
IN+
Input of voltage (0-10V) or current (4-20mA) reference signal
Connect to the positive pole of the reference signal generator.
Internal resistance with voltage input: >10kΩ. Use reference signal generator with low
impedance and with output current >1mA@10V.
Internal resistance with current input: 100Ω.
It is mandatory to connect all negative poles of the power supply and the reference signal
generator together.
2
N.C.
NOT CONNECTED
5
Dout
Digital output signal (0-24V)
Connect to a digital input. If the input is of the NPN type, use pin 1 (24VDC) as reference of
digital input; otherwise if the input is of the PNP type, use pin 2 (GND) as reference of digital
input. Output resistance: >15MΩ. Max current: 50mA.