CR300-Series Datalogger
24
data table will update at its own data table interval or according to a trigger set
within the program.
The data file consists of five or more rows. Each row consists of columns, or
fields. The first four rows constitute the file header. Subsequent rows contain
data records.
TABLE 5-2. Typical Data Table
TOA5 CR300Series CR300 142 CR300.Std.01 CPU:MyTemperature.CR300 1958 OneMin
TIMESTAMP RECORD BattV_Avg PTemp_C_Avg Temp_C_Avg
TS RN Volts Deg C Deg C
Avg Avg Avg
2016-03-08 14:24:00 0 0 21.84 20.71
2016-03-08 14:25:00 1 0 21.84 20.63
2016-03-08 14:26:00 2 0 21.84 20.63
2016-03-08 14:27:00 3 0 21.85 20.62
2016-03-08 14:28:00 4 0 21.85 20.52
2016-03-08 14:29:00 5 0 21.85 20.64
Each data table is associated with overhead information, referred to as “table
definitions,that becomes part of the file header (first few lines of the file)
when data are downloaded to a PC.
The first header row of the data table is the environment line. It consists of
eight fields, listed in TABLE 5-3.
TABLE 5-3. TOA5 Environment Line
Field Entry in TABLE 5-2 Description Changed By
1 TOA5 Table output format LoggerNet Setup or Connect Custom
Collection | File Format
2 CR300Series Station name Device Configuration Utility or
CRBasic program
3 CR300 Datalogger model
4 142 Datalogger serial number
5 CR300.Std.01 Datalogger OS version New OS
6 CPU:MyTemperature.CR300 Datalogger program name New program
7 1958 Datalogger program signature New or revised program
8 OneMin Table name Revised program
The second header row reports fieldnames. This row consists of fieldnames
that identify the name of individual fields as given in the datalogger program.
Default fieldnames are a combination of the variable names (or aliases) from
which data are derived and a three-letter suffix. The suffix is an abbreviation of
the data process that outputs the data to storage. See TABLE 5-4 for a list of
these abbreviations.