EasyManua.ls Logo

Campbell CR300 series - High-Frequency Input; Low-Level AC Input; Period Averaging - Specifications

Campbell CR300 series
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CR300-Series Datalogger
46
7.5.2 High-Frequency Input
Terminals: SE terminals 1-4
P_LL
P_SW
C1-C2
Maximum Input Frequency
SE 1-4: 35 kHz
P_LL: 20 kHz
P_SW: 35 kHz
C1-C2: 3 kHz
7.5.3 Low-Level AC Input
Terminal: P_LL
Range: See TABLE 7-5, Low-Level AC
Ranges
(p. 46)
Input Hysteresis: 12 mV at 1 Hz
TABLE 7-5. Low-Level AC Ranges
1
Sine Wave Input
(mV
RMS
)
Range
(Hz)
20 1.0 to 20
200 0.5 to 200
2000 0.3 to 10,000
5000 0.3 to 20,000
1
AC coupling removes AC offsets up to ±0.05 V
7.6 Period AveragingSpecifications
Up to four analog inputs may be configured for period averaging.
Terminals: SE terminals 1-4
Frequency Range: 5 Hz to 200 kHz
Voltage Range: 0 to 3.3 V
Accuracy: ±(0.01% of reading + resolution)
Resolution: 13 ns ÷ number of cycles
Minimum Pulse Width: 2.5 µs
High Threshold: 2.5 V