EasyManua.ls Logo

Campbell CR300 series - Power Requirements - Specifications; Compliance - Specifications; Physical - Specifications

Campbell CR300 series
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CR300-Series Datalogger
49
7.12 Power RequirementsSpecifications
Charger Input: CHG+ and CHG- terminals
16 32 Vdc
Current limited to 0.9 A maximum.
Power converter or solar panel input.
External Batteries: BAT+ and BAT- terminals
10 16 Vdc input
12 Vdc, lead-acid 7 Ah battery, typical.
Internal Lithium Battery: 3 V coin cell CR2016 (Energizer) for battery-
backed clock
6-year life with no external power source.
Typical Power Requirements
Sleep: 1.5 mA
Active 1 Hz Scan
1
: 5 mA
USB Power: For programming and limited functionality.
VX1 VX2 range reduced to 150 to 2500 mV.
SW12V nonoperational. Control ports output
4.75 V with limited current.
7.13 ComplianceSpecifications
CE: View the EU Declaration of Conformity at
www.campbellsci.com/cr300.
Shock and Vibration: ASTM D4169-09
Protection: IP30
7.14 PhysicalSpecifications
Dimensions: 14.0 x 7.6 x 5.1 cm (5.5 x 3.0 x 2.0 in)
additional clearance required for cables and
leads
Weight/Mass: 242 g (8.5 oz)
Case Material: Powder-coated aluminum