EN-19
Under any circumstances, make sure the Induction cooker hob is well
ventilated and the air inlet and outlet are not blocked. Ensure the Induction
cooker hob is in good work state. As shown below
Note: The safety distance between the hotplate and the cupboard
above the hotplate should be at least 760mm.
A (mm) B (mm) C (mm) D E
760 50 mini 30 mini Air intake Air exit 10
Before you install the hob, make sure that
the work surface is square and level, and no structural members interfere
with space requirements
the work surface is made of a heat-resistant material
if the hob is installed above an oven, the oven has a built-in cooling fan
the installation will comply with all clearance requirements and
applicable standards and regulations
a suitable isolating switch providing full disconnection from the mains
power supply is incorporated in the permanent wiring, mounted and
positioned to comply with the local wiring rules and regulations
The isolating switch must be of an approved type and provide a 3 mm
air gap contact separation in all poles (or in all active [phase] conductors
if the local wiring rules allow for this variation of the requirements).