EasyManua.ls Logo

Candy CY-09FAOUT - Installation Procedure Steps; Vacuum Pump Method

Candy CY-09FAOUT
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.
CY-09TAOUT
CY-12TAOUT
CY-09FAOUT
CY-12FAOUT
Liquid pipe φ6.35×0.8mm
Gas pipe φ9.52×0.8mm
CY-18TAOUT
CY-24TAOUT
CY-18FAOUT
Liquid pipe φ6.35×0.8mm
Install the removed flare nuts to the
pipes to be connected,then flare the pipes
Gas pipe φ12.0.8mm
2.
Connection of pipes
To bend a pi
pe, give the roundness as large as possible not to crush the pipe ,
and the bending radius should be 30 to 40
mm or longer.
Connecting the pipe of gas side rst makes working easier.
The connection pipe is specialized for R32.
Half union
Flare nut
Forced fastening without careful centering may
damage the threads and cause a leakage of gas.
Pipe Diameter( ) Fastening torque
Liquid side6.35mm(1/4")
18~20N.m
Liquid/Gas side9.52mm(3/8")
30~35N.m
Gas side 12.7mm(1/2")
35~45N.m
Spanner
Torque wrench
Gas side 15.88mm(5/8")
45~55N.m
Be careful that matters, such as wastes of sand
s,water,
, etc. shall not enter the pipe.
CAUTION
The standard pipe length is Cm. If it is over D m, the function of the unit will be affected. If the pipe
has
to be lengthened, the refrigerant should be charged,
according to E g/m. But the charge of refrigerant
must
be conducted by profes
sional air conditioner engineer. Before adding additional refrigerant,
perform
air
purging from the refrigerant pipes and indoor unit using a vacuum pump,then
charge
additional refrigerant.
Outdoor unit
Outdoor Unit Amax Bmax Bmin C D E
CY-09TAOUT 10 20 3 5 5 20
B
Indoor unit
B
CY-12TAOUT
CY-09FAOUT
CY-12FAOUT
A
Indoor unit
10 20 3 5 7 20
A
Outdoor unit
CY-18FAOUT
CY-18TAOUT
CY-24TAOUT
Max.Elevation:
Amax
In case the elevation A is more
than 5m, oil trap shoud be
installed every 5~7
Max. Length:
Bmax
Mi n. Length:
B min
In case the pipe length B is
more thanDm, the refrigerant
should be charged, according
to E g/m.
15 25 3 5 7 20
Outdoor unit
B
Oil trap
Indoor unit
A
22