ROOM AIR CONDITIONER
INSTALLATION MANUAL
CY-09FAOUT
CY-12FAOUT
CY-18FAOUT
CY-09TAOUT
CY-12TAOUT
CY-18TAOUT
CY-24TAOUT
CY-2T14AOUT
CY-2T18AOUT
CY-2M14AOUT
CY-2M18AOUT
Please read this manual carefully before installation.
This appliance is filled with R32.
Keep this operation manual for future reference.
Manufactured: Qingdao Haier Air Conditioner General Co, Ltd.
Question and Answer IconNeed help?

Do you have a question about the Candy CY-09FAOUT and is the answer not in the manual?

Summary

Key Safety Warnings

Electrical Safety and Installation Compliance

Covers compliance for electrical work, wiring, grounding, circuit breakers, and installation procedures.

Refrigerant Handling and Fire Prevention

Covers refrigerant leaks, fire hazards, and approved methods for handling.

Room Requirements and User Safety

Covers child safety, room area, ventilation, and proper disposal procedures.

Important Cautions and Precautions

Flammable Gas and Tool Precautions

Covers danger of flammable gas, flare nut tightening, and specialized tools for R32.

Environmental and Refrigerant Considerations

Covers animal protection, cleanliness, refrigerant handling, and corrosion.

European Regulations and Model Conformity

Product Compliance Standards

Covers conformity with directives like CE, RED, F-GAS, ENERGY, REACH, and RoHS.

Refrigerant Information for R32 Units

R32 Refrigerant Properties

Covers refrigerant type, GWP, and greenhouse gas impact.

Product Disposal and WEEE Requirements

Product Disposal and Recycling

Covers WEEE, product marking, and specialized treatment for disposal.

Loading and Unloading Procedures

Handling, Training, and Safety Equipment

Covers careful handling, training, and safety equipment during loading/unloading.

Transporting Management Guidelines

Vehicle Safety and Operation

Covers regulations, vehicle equipment, driving practices, and load safety.

Storage Guidelines

Package Integrity and Quantity Limits

Covers package integrity to prevent leakage and storage quantity limits.

Installation Precautions and Safety

Site Selection and Preparation

Covers minimum room area, installation site, and preparation steps.

Piping, Wiring, and Leak Control

Covers pipe/wire connections, drain management, refrigerant leak procedures, and ventilation.

General Installation Safety

Covers fire, static, placement, and handling of damaged units.

General Safety Awareness

Operational Safety and Fire Prevention

Covers procedures, area control, fire prevention, and site inspection.

Unit Unpacking Inspection

Indoor and Outdoor Unit Leak Checks

Covers inspection of indoor and outdoor units for refrigerant leakage.

Installation Environment Inspection

Room Area and Electrical Checks

Covers minimum room area, surroundings, electrical supply, and wall checks.

Installation Safety Principles

Ventilation, Static Control, and Leak Response

Covers ventilation, anti-static measures, refrigerant leak response, and unit placement.

Electrical Safety Requirements for Installation

Wiring, Grounding, and Circuit Protection

Covers wiring standards, earthing, circuit breakers, and dedicated circuits.

Installer Qualification Requirements

Installer Certification

States the requirement for a qualification certificate for installers.

Indoor Unit Installation Steps

Wall Panel, Piping Layout, and Nitrogen Charging

Covers fixation, piping layout, and nitrogen charging/leak detection.

Outdoor Unit Installation Steps

Fixation and Connection Procedures

Covers fixing the unit to its support and connecting pipes.

Outdoor Unit Installation Steps

Vacuumizing Procedure

Details vacuum pump usage, pressure checks, and operating procedures.

Leak Detection Methods

Describes methods for checking pipe joints for leaks using various tools.

Post-installation Inspection and Test Run

Covers inspection items and test run procedures.

Unit Relocation Procedures

System Disassembly and Refrigerant Recovery

Covers inspection, safety discharge, recovery, cleaning, and disassembly steps.

Maintenance Instructions and Precautions

General Maintenance Precautions

Covers faults requiring site maintenance, disassembly, and pipe replacement.

Maintenance Personnel Qualifications

Covers certification requirements for maintenance personnel.

Maintenance Environment Inspection

Ventilation and Fire Safety

Covers ventilation, fire source prohibition, and phone usage during maintenance.

Maintenance Site Requirements

Site Preparation and Safety Equipment

Covers site preparation, ventilation, leak detection, and gas cylinder safety.

Leak Detection Methods

Leak Detection Procedures and Calibration

Covers leak detection methods, calibration, and fluid usage.

Safety Principles for Maintenance

Operational Safety and Grounding

Covers ventilation, fire safety, static control, leak response, and grounding.

Maintenance Requirements and Procedures

System Cleaning and Refrigerant Handling

Covers system cleaning, vacuumizing, refrigerant handling, and charging.

Maintenance of Electrical Components

Component Safety Checks and Procedures

Covers leak detection, component safety, and power-off procedures.

Maintenance of Intrinsically Safe Elements

Pre-maintenance Checks and Component Replacement

Covers leak detection, earthing, voltage/current limits, and component replacement.

Refrigerant Removal and Vacuumizing

Procedure Overview and Safety

Covers refrigerant clearing, purging, vacuumizing, and safety considerations.

Welding Procedures During Maintenance

Site Preparation and Pipe Cutting

Covers ventilation, vacuumizing, refrigerant discharge, and pipe cutting.

Refrigerant Charging Guidelines

Charging Guidelines and Cautions

Covers charging guidelines, pipe length, cylinder handling, and cautions.

Refrigerant Storage Site Requirements

Cylinder Storage and Tool Management

Covers cylinder storage, temperature, ventilation, and tool management.

Scrapping and Refrigerant Recovery

Scrapping Preparation and Process

Covers preparation, refrigerant recovery, equipment, and personnel guidance.

Scrapping and Refrigerant Recovery

Recovery Process and Handling

Covers recovery equipment, weighing, hose usage, and transport.

Compressor Oil Handling

Covers compressor oil vacuumizing and safety during discharge.

Indoor and Outdoor Unit Installation Diagrams

Unit Placement and Clearance

Covers arrangement of piping, clearance requirements, and floor distance.

Outdoor Unit Fixing and Support

Covers fixing the unit to foundation, walls, roofs, and earthquake/wind considerations.

Unit Component Identification

Identifies air outlets, inlets, piping, and drain hose.

Indoor and Outdoor Unit Installation Diagrams

Piping Arrangement and Connection Details

Covers piping directions, optional parts for piping, and connections.

Outdoor Unit Fixing Methods

Covers fixing to concrete, walls, roofs, and vibration-proof mats.

Unit Markings and Drainage

Covers part numbers, floor distance, and drain pipe guidance.

General Safety Precautions

General Warnings and Symbols

Covers WARNING/CAUTION/INSTRUCTIONS symbols and general advice.

Operational Safety Warnings

Covers abnormal phenomena, ventilation, base checks, fan exposure, maintenance, and installation environment.

Electrical and Fire Safety

Covers damp hands, fuses, installation environment, refrigerant leaks, and earthing.

General Safety Precautions

Professional Installation and Unit Stability

Covers professional installation, unit stability, wiring, and earthquake/typhoon measures.

Unit Modifications and Repairs

Covers avoiding changes, consulting dealer for repairs, and refrigerant type.

Heat Exchanger and Leak Handling

Covers touching fins, refrigerant leaks, safety feature defeat, and checking after service.

Safety Precautions for R32 Refrigerant Units

Piping and Contaminant Precautions

Covers existing piping, cleaning, and contaminants.

Tool and Refrigerant Compatibility

Covers vacuum pumps, R32 specific tools, and leak detectors.

Storage and Lubricant Precautions

Covers piping storage, lubricants, and refrigerant charging.

Installation Environment and Noise

Covers flammable gas, food preservation, unusual environments, and hospital noise.

Installation and Electrical Work Safety Precautions

Grounding and Wiring Safety

Covers grounding rules, wire tension, explosion-proof breakers, and packing disposal.

Safety Precautions Before Test Run

Pre-Operation Safety Checks

Covers operating with wet hands, touching refrigerant pipes, and unit panels.

Post-Operation Procedures

Covers power-off delay and air filter usage.

Installation Procedure Steps

Required Accessories and Site Selection

Covers edging for wires and selecting the installation place.

Outdoor Unit Installation and Foundation

Covers fixing the unit on a foundation and ensuring proper drainage.

Unit Dimensions and Clearances

Covers installation dimensions and required clearances.

Installation Procedure Steps

Piping Size Specifications

Covers pipe sizes for different models and connection requirements.

Pipe Connection and Fastening

Covers bending, connecting gas side first, and fastening torque.

Pipe Length and Refrigerant Charging Caution

Covers pipe length effects and caution for refrigerant charging.

Installation Procedure Steps

Piping Size and Adapter Requirements

Covers pipe sizes and the need for a pipe adapter for 5kw units.

Pipe Connection Techniques

Covers bending, connecting gas side first, and fastening torque.

Refrigerant Charging and Pipe Length Caution

Covers pipe length effects and caution for refrigerant charging.

Installation Procedure Steps

Air Tightness Test Procedure

Covers nitrogen tank pressurization, leak checking, and pressure variation correction.

Installation Procedure Steps

Vacuum Pump Method

Details using a vacuum pump, gauge manifold, vacuumizing, and checking for leaks.

Installation Procedure Steps

Electrical Wiring Safety and Precautions

Covers turning off power, ground connections, authorized personnel, wire types, and terminal blocks.

Power Supply and Wire Sizing

Covers selecting wire sizes and circuit protection.

Wiring Procedure and Diagrams

Covers removing screws, connecting wires, routing, and diagrams.

Outdoor Unit Troubleshooting Guide

Pre-Test Run Checks

Covers crankcase heater energization before test run.

Test Run Procedures and Checks

Covers running the unit and checking pressures and temperatures.

Trouble Codes and Diagnosis

Lists flash times, trouble descriptions, and analysis for failures.

Product Fiche Details

General Information and Specifications

Covers supplier, model types, sound power, refrigerant, GWP, and leakage impact.

Cooling Performance Data

Covers SEER, energy class, Qce, and Pdesignc for cooling mode.

Heating Performance Data (Average Climate)

Covers SCOP, energy class, Qhe, Pdesignh for average climate.

Heating Performance Data (Warm Climate)

Covers SCOP, energy class, Qhe, Pdesignh for warm climate.

Summary

Key Safety Warnings

Electrical Safety and Installation Compliance

Covers compliance for electrical work, wiring, grounding, circuit breakers, and installation procedures.

Refrigerant Handling and Fire Prevention

Covers refrigerant leaks, fire hazards, and approved methods for handling.

Room Requirements and User Safety

Covers child safety, room area, ventilation, and proper disposal procedures.

Important Cautions and Precautions

Flammable Gas and Tool Precautions

Covers danger of flammable gas, flare nut tightening, and specialized tools for R32.

Environmental and Refrigerant Considerations

Covers animal protection, cleanliness, refrigerant handling, and corrosion.

European Regulations and Model Conformity

Product Compliance Standards

Covers conformity with directives like CE, RED, F-GAS, ENERGY, REACH, and RoHS.

Refrigerant Information for R32 Units

R32 Refrigerant Properties

Covers refrigerant type, GWP, and greenhouse gas impact.

Product Disposal and WEEE Requirements

Product Disposal and Recycling

Covers WEEE, product marking, and specialized treatment for disposal.

Loading and Unloading Procedures

Handling, Training, and Safety Equipment

Covers careful handling, training, and safety equipment during loading/unloading.

Transporting Management Guidelines

Vehicle Safety and Operation

Covers regulations, vehicle equipment, driving practices, and load safety.

Storage Guidelines

Package Integrity and Quantity Limits

Covers package integrity to prevent leakage and storage quantity limits.

Installation Precautions and Safety

Site Selection and Preparation

Covers minimum room area, installation site, and preparation steps.

Piping, Wiring, and Leak Control

Covers pipe/wire connections, drain management, refrigerant leak procedures, and ventilation.

General Installation Safety

Covers fire, static, placement, and handling of damaged units.

General Safety Awareness

Operational Safety and Fire Prevention

Covers procedures, area control, fire prevention, and site inspection.

Unit Unpacking Inspection

Indoor and Outdoor Unit Leak Checks

Covers inspection of indoor and outdoor units for refrigerant leakage.

Installation Environment Inspection

Room Area and Electrical Checks

Covers minimum room area, surroundings, electrical supply, and wall checks.

Installation Safety Principles

Ventilation, Static Control, and Leak Response

Covers ventilation, anti-static measures, refrigerant leak response, and unit placement.

Electrical Safety Requirements for Installation

Wiring, Grounding, and Circuit Protection

Covers wiring standards, earthing, circuit breakers, and dedicated circuits.

Installer Qualification Requirements

Installer Certification

States the requirement for a qualification certificate for installers.

Indoor Unit Installation Steps

Wall Panel, Piping Layout, and Nitrogen Charging

Covers fixation, piping layout, and nitrogen charging/leak detection.

Outdoor Unit Installation Steps

Fixation and Connection Procedures

Covers fixing the unit to its support and connecting pipes.

Outdoor Unit Installation Steps

Vacuumizing Procedure

Details vacuum pump usage, pressure checks, and operating procedures.

Leak Detection Methods

Describes methods for checking pipe joints for leaks using various tools.

Post-installation Inspection and Test Run

Covers inspection items and test run procedures.

Unit Relocation Procedures

System Disassembly and Refrigerant Recovery

Covers inspection, safety discharge, recovery, cleaning, and disassembly steps.

Maintenance Instructions and Precautions

General Maintenance Precautions

Covers faults requiring site maintenance, disassembly, and pipe replacement.

Maintenance Personnel Qualifications

Covers certification requirements for maintenance personnel.

Maintenance Environment Inspection

Ventilation and Fire Safety

Covers ventilation, fire source prohibition, and phone usage during maintenance.

Maintenance Site Requirements

Site Preparation and Safety Equipment

Covers site preparation, ventilation, leak detection, and gas cylinder safety.

Leak Detection Methods

Leak Detection Procedures and Calibration

Covers leak detection methods, calibration, and fluid usage.

Safety Principles for Maintenance

Operational Safety and Grounding

Covers ventilation, fire safety, static control, leak response, and grounding.

Maintenance Requirements and Procedures

System Cleaning and Refrigerant Handling

Covers system cleaning, vacuumizing, refrigerant handling, and charging.

Maintenance of Electrical Components

Component Safety Checks and Procedures

Covers leak detection, component safety, and power-off procedures.

Maintenance of Intrinsically Safe Elements

Pre-maintenance Checks and Component Replacement

Covers leak detection, earthing, voltage/current limits, and component replacement.

Refrigerant Removal and Vacuumizing

Procedure Overview and Safety

Covers refrigerant clearing, purging, vacuumizing, and safety considerations.

Welding Procedures During Maintenance

Site Preparation and Pipe Cutting

Covers ventilation, vacuumizing, refrigerant discharge, and pipe cutting.

Refrigerant Charging Guidelines

Charging Guidelines and Cautions

Covers charging guidelines, pipe length, cylinder handling, and cautions.

Refrigerant Storage Site Requirements

Cylinder Storage and Tool Management

Covers cylinder storage, temperature, ventilation, and tool management.

Scrapping and Refrigerant Recovery

Scrapping Preparation and Process

Covers preparation, refrigerant recovery, equipment, and personnel guidance.

Scrapping and Refrigerant Recovery

Recovery Process and Handling

Covers recovery equipment, weighing, hose usage, and transport.

Compressor Oil Handling

Covers compressor oil vacuumizing and safety during discharge.

Indoor and Outdoor Unit Installation Diagrams

Unit Placement and Clearance

Covers arrangement of piping, clearance requirements, and floor distance.

Outdoor Unit Fixing and Support

Covers fixing the unit to foundation, walls, roofs, and earthquake/wind considerations.

Unit Component Identification

Identifies air outlets, inlets, piping, and drain hose.

Indoor and Outdoor Unit Installation Diagrams

Piping Arrangement and Connection Details

Covers piping directions, optional parts for piping, and connections.

Outdoor Unit Fixing Methods

Covers fixing to concrete, walls, roofs, and vibration-proof mats.

Unit Markings and Drainage

Covers part numbers, floor distance, and drain pipe guidance.

General Safety Precautions

General Warnings and Symbols

Covers WARNING/CAUTION/INSTRUCTIONS symbols and general advice.

Operational Safety Warnings

Covers abnormal phenomena, ventilation, base checks, fan exposure, maintenance, and installation environment.

Electrical and Fire Safety

Covers damp hands, fuses, installation environment, refrigerant leaks, and earthing.

General Safety Precautions

Professional Installation and Unit Stability

Covers professional installation, unit stability, wiring, and earthquake/typhoon measures.

Unit Modifications and Repairs

Covers avoiding changes, consulting dealer for repairs, and refrigerant type.

Heat Exchanger and Leak Handling

Covers touching fins, refrigerant leaks, safety feature defeat, and checking after service.

Safety Precautions for R32 Refrigerant Units

Piping and Contaminant Precautions

Covers existing piping, cleaning, and contaminants.

Tool and Refrigerant Compatibility

Covers vacuum pumps, R32 specific tools, and leak detectors.

Storage and Lubricant Precautions

Covers piping storage, lubricants, and refrigerant charging.

Installation Environment and Noise

Covers flammable gas, food preservation, unusual environments, and hospital noise.

Installation and Electrical Work Safety Precautions

Grounding and Wiring Safety

Covers grounding rules, wire tension, explosion-proof breakers, and packing disposal.

Safety Precautions Before Test Run

Pre-Operation Safety Checks

Covers operating with wet hands, touching refrigerant pipes, and unit panels.

Post-Operation Procedures

Covers power-off delay and air filter usage.

Installation Procedure Steps

Required Accessories and Site Selection

Covers edging for wires and selecting the installation place.

Outdoor Unit Installation and Foundation

Covers fixing the unit on a foundation and ensuring proper drainage.

Unit Dimensions and Clearances

Covers installation dimensions and required clearances.

Installation Procedure Steps

Piping Size Specifications

Covers pipe sizes for different models and connection requirements.

Pipe Connection and Fastening

Covers bending, connecting gas side first, and fastening torque.

Pipe Length and Refrigerant Charging Caution

Covers pipe length effects and caution for refrigerant charging.

Installation Procedure Steps

Piping Size and Adapter Requirements

Covers pipe sizes and the need for a pipe adapter for 5kw units.

Pipe Connection Techniques

Covers bending, connecting gas side first, and fastening torque.

Refrigerant Charging and Pipe Length Caution

Covers pipe length effects and caution for refrigerant charging.

Installation Procedure Steps

Air Tightness Test Procedure

Covers nitrogen tank pressurization, leak checking, and pressure variation correction.

Installation Procedure Steps

Vacuum Pump Method

Details using a vacuum pump, gauge manifold, vacuumizing, and checking for leaks.

Installation Procedure Steps

Electrical Wiring Safety and Precautions

Covers turning off power, ground connections, authorized personnel, wire types, and terminal blocks.

Power Supply and Wire Sizing

Covers selecting wire sizes and circuit protection.

Wiring Procedure and Diagrams

Covers removing screws, connecting wires, routing, and diagrams.

Outdoor Unit Troubleshooting Guide

Pre-Test Run Checks

Covers crankcase heater energization before test run.

Test Run Procedures and Checks

Covers running the unit and checking pressures and temperatures.

Trouble Codes and Diagnosis

Lists flash times, trouble descriptions, and analysis for failures.

Product Fiche Details

General Information and Specifications

Covers supplier, model types, sound power, refrigerant, GWP, and leakage impact.

Cooling Performance Data

Covers SEER, energy class, Qce, and Pdesignc for cooling mode.

Heating Performance Data (Average Climate)

Covers SCOP, energy class, Qhe, Pdesignh for average climate.

Heating Performance Data (Warm Climate)

Covers SCOP, energy class, Qhe, Pdesignh for warm climate.

Candy CY-09FAOUT Specifications

General IconGeneral
Power Supply220-240V, 50Hz
Air Flow450 m³/h
TypeSplit System
Cooling Capacity9000 BTU/h
Cooling power9000 BTU/h
Heating Capacity9000 BTU/h
Heating power9000 BTU/h
Dimensions (Outdoor Unit)700 mm