Covers compliance for electrical work, wiring, grounding, circuit breakers, and installation procedures.
Covers refrigerant leaks, fire hazards, and approved methods for handling.
Covers child safety, room area, ventilation, and proper disposal procedures.
Covers danger of flammable gas, flare nut tightening, and specialized tools for R32.
Covers animal protection, cleanliness, refrigerant handling, and corrosion.
Covers conformity with directives like CE, RED, F-GAS, ENERGY, REACH, and RoHS.
Covers refrigerant type, GWP, and greenhouse gas impact.
Covers WEEE, product marking, and specialized treatment for disposal.
Covers careful handling, training, and safety equipment during loading/unloading.
Covers regulations, vehicle equipment, driving practices, and load safety.
Covers package integrity to prevent leakage and storage quantity limits.
Covers minimum room area, installation site, and preparation steps.
Covers pipe/wire connections, drain management, refrigerant leak procedures, and ventilation.
Covers fire, static, placement, and handling of damaged units.
Covers procedures, area control, fire prevention, and site inspection.
Covers inspection of indoor and outdoor units for refrigerant leakage.
Covers minimum room area, surroundings, electrical supply, and wall checks.
Covers ventilation, anti-static measures, refrigerant leak response, and unit placement.
Covers wiring standards, earthing, circuit breakers, and dedicated circuits.
States the requirement for a qualification certificate for installers.
Covers fixation, piping layout, and nitrogen charging/leak detection.
Covers fixing the unit to its support and connecting pipes.
Details vacuum pump usage, pressure checks, and operating procedures.
Describes methods for checking pipe joints for leaks using various tools.
Covers inspection items and test run procedures.
Covers inspection, safety discharge, recovery, cleaning, and disassembly steps.
Covers faults requiring site maintenance, disassembly, and pipe replacement.
Covers certification requirements for maintenance personnel.
Covers ventilation, fire source prohibition, and phone usage during maintenance.
Covers site preparation, ventilation, leak detection, and gas cylinder safety.
Covers leak detection methods, calibration, and fluid usage.
Covers ventilation, fire safety, static control, leak response, and grounding.
Covers system cleaning, vacuumizing, refrigerant handling, and charging.
Covers leak detection, component safety, and power-off procedures.
Covers leak detection, earthing, voltage/current limits, and component replacement.
Covers refrigerant clearing, purging, vacuumizing, and safety considerations.
Covers ventilation, vacuumizing, refrigerant discharge, and pipe cutting.
Covers charging guidelines, pipe length, cylinder handling, and cautions.
Covers cylinder storage, temperature, ventilation, and tool management.
Covers preparation, refrigerant recovery, equipment, and personnel guidance.
Covers recovery equipment, weighing, hose usage, and transport.
Covers compressor oil vacuumizing and safety during discharge.
Covers arrangement of piping, clearance requirements, and floor distance.
Covers fixing the unit to foundation, walls, roofs, and earthquake/wind considerations.
Identifies air outlets, inlets, piping, and drain hose.
Covers piping directions, optional parts for piping, and connections.
Covers fixing to concrete, walls, roofs, and vibration-proof mats.
Covers part numbers, floor distance, and drain pipe guidance.
Covers WARNING/CAUTION/INSTRUCTIONS symbols and general advice.
Covers abnormal phenomena, ventilation, base checks, fan exposure, maintenance, and installation environment.
Covers damp hands, fuses, installation environment, refrigerant leaks, and earthing.
Covers professional installation, unit stability, wiring, and earthquake/typhoon measures.
Covers avoiding changes, consulting dealer for repairs, and refrigerant type.
Covers touching fins, refrigerant leaks, safety feature defeat, and checking after service.
Covers existing piping, cleaning, and contaminants.
Covers vacuum pumps, R32 specific tools, and leak detectors.
Covers piping storage, lubricants, and refrigerant charging.
Covers flammable gas, food preservation, unusual environments, and hospital noise.
Covers grounding rules, wire tension, explosion-proof breakers, and packing disposal.
Covers operating with wet hands, touching refrigerant pipes, and unit panels.
Covers power-off delay and air filter usage.
Covers edging for wires and selecting the installation place.
Covers fixing the unit on a foundation and ensuring proper drainage.
Covers installation dimensions and required clearances.
Covers pipe sizes for different models and connection requirements.
Covers bending, connecting gas side first, and fastening torque.
Covers pipe length effects and caution for refrigerant charging.
Covers pipe sizes and the need for a pipe adapter for 5kw units.
Covers bending, connecting gas side first, and fastening torque.
Covers pipe length effects and caution for refrigerant charging.
Covers nitrogen tank pressurization, leak checking, and pressure variation correction.
Details using a vacuum pump, gauge manifold, vacuumizing, and checking for leaks.
Covers turning off power, ground connections, authorized personnel, wire types, and terminal blocks.
Covers selecting wire sizes and circuit protection.
Covers removing screws, connecting wires, routing, and diagrams.
Covers crankcase heater energization before test run.
Covers running the unit and checking pressures and temperatures.
Lists flash times, trouble descriptions, and analysis for failures.
Covers supplier, model types, sound power, refrigerant, GWP, and leakage impact.
Covers SEER, energy class, Qce, and Pdesignc for cooling mode.
Covers SCOP, energy class, Qhe, Pdesignh for average climate.
Covers SCOP, energy class, Qhe, Pdesignh for warm climate.
Covers compliance for electrical work, wiring, grounding, circuit breakers, and installation procedures.
Covers refrigerant leaks, fire hazards, and approved methods for handling.
Covers child safety, room area, ventilation, and proper disposal procedures.
Covers danger of flammable gas, flare nut tightening, and specialized tools for R32.
Covers animal protection, cleanliness, refrigerant handling, and corrosion.
Covers conformity with directives like CE, RED, F-GAS, ENERGY, REACH, and RoHS.
Covers refrigerant type, GWP, and greenhouse gas impact.
Covers WEEE, product marking, and specialized treatment for disposal.
Covers careful handling, training, and safety equipment during loading/unloading.
Covers regulations, vehicle equipment, driving practices, and load safety.
Covers package integrity to prevent leakage and storage quantity limits.
Covers minimum room area, installation site, and preparation steps.
Covers pipe/wire connections, drain management, refrigerant leak procedures, and ventilation.
Covers fire, static, placement, and handling of damaged units.
Covers procedures, area control, fire prevention, and site inspection.
Covers inspection of indoor and outdoor units for refrigerant leakage.
Covers minimum room area, surroundings, electrical supply, and wall checks.
Covers ventilation, anti-static measures, refrigerant leak response, and unit placement.
Covers wiring standards, earthing, circuit breakers, and dedicated circuits.
States the requirement for a qualification certificate for installers.
Covers fixation, piping layout, and nitrogen charging/leak detection.
Covers fixing the unit to its support and connecting pipes.
Details vacuum pump usage, pressure checks, and operating procedures.
Describes methods for checking pipe joints for leaks using various tools.
Covers inspection items and test run procedures.
Covers inspection, safety discharge, recovery, cleaning, and disassembly steps.
Covers faults requiring site maintenance, disassembly, and pipe replacement.
Covers certification requirements for maintenance personnel.
Covers ventilation, fire source prohibition, and phone usage during maintenance.
Covers site preparation, ventilation, leak detection, and gas cylinder safety.
Covers leak detection methods, calibration, and fluid usage.
Covers ventilation, fire safety, static control, leak response, and grounding.
Covers system cleaning, vacuumizing, refrigerant handling, and charging.
Covers leak detection, component safety, and power-off procedures.
Covers leak detection, earthing, voltage/current limits, and component replacement.
Covers refrigerant clearing, purging, vacuumizing, and safety considerations.
Covers ventilation, vacuumizing, refrigerant discharge, and pipe cutting.
Covers charging guidelines, pipe length, cylinder handling, and cautions.
Covers cylinder storage, temperature, ventilation, and tool management.
Covers preparation, refrigerant recovery, equipment, and personnel guidance.
Covers recovery equipment, weighing, hose usage, and transport.
Covers compressor oil vacuumizing and safety during discharge.
Covers arrangement of piping, clearance requirements, and floor distance.
Covers fixing the unit to foundation, walls, roofs, and earthquake/wind considerations.
Identifies air outlets, inlets, piping, and drain hose.
Covers piping directions, optional parts for piping, and connections.
Covers fixing to concrete, walls, roofs, and vibration-proof mats.
Covers part numbers, floor distance, and drain pipe guidance.
Covers WARNING/CAUTION/INSTRUCTIONS symbols and general advice.
Covers abnormal phenomena, ventilation, base checks, fan exposure, maintenance, and installation environment.
Covers damp hands, fuses, installation environment, refrigerant leaks, and earthing.
Covers professional installation, unit stability, wiring, and earthquake/typhoon measures.
Covers avoiding changes, consulting dealer for repairs, and refrigerant type.
Covers touching fins, refrigerant leaks, safety feature defeat, and checking after service.
Covers existing piping, cleaning, and contaminants.
Covers vacuum pumps, R32 specific tools, and leak detectors.
Covers piping storage, lubricants, and refrigerant charging.
Covers flammable gas, food preservation, unusual environments, and hospital noise.
Covers grounding rules, wire tension, explosion-proof breakers, and packing disposal.
Covers operating with wet hands, touching refrigerant pipes, and unit panels.
Covers power-off delay and air filter usage.
Covers edging for wires and selecting the installation place.
Covers fixing the unit on a foundation and ensuring proper drainage.
Covers installation dimensions and required clearances.
Covers pipe sizes for different models and connection requirements.
Covers bending, connecting gas side first, and fastening torque.
Covers pipe length effects and caution for refrigerant charging.
Covers pipe sizes and the need for a pipe adapter for 5kw units.
Covers bending, connecting gas side first, and fastening torque.
Covers pipe length effects and caution for refrigerant charging.
Covers nitrogen tank pressurization, leak checking, and pressure variation correction.
Details using a vacuum pump, gauge manifold, vacuumizing, and checking for leaks.
Covers turning off power, ground connections, authorized personnel, wire types, and terminal blocks.
Covers selecting wire sizes and circuit protection.
Covers removing screws, connecting wires, routing, and diagrams.
Covers crankcase heater energization before test run.
Covers running the unit and checking pressures and temperatures.
Lists flash times, trouble descriptions, and analysis for failures.
Covers supplier, model types, sound power, refrigerant, GWP, and leakage impact.
Covers SEER, energy class, Qce, and Pdesignc for cooling mode.
Covers SCOP, energy class, Qhe, Pdesignh for average climate.
Covers SCOP, energy class, Qhe, Pdesignh for warm climate.
| Power Supply | 220-240V, 50Hz |
|---|---|
| Air Flow | 450 m³/h |
| Type | Split System |
| Cooling Capacity | 9000 BTU/h |
| Cooling power | 9000 BTU/h |
| Heating Capacity | 9000 BTU/h |
| Heating power | 9000 BTU/h |
| Dimensions (Outdoor Unit) | 700 mm |