9. Number of Final Flag Sequences: SW04 bit 2 of Service Soft Switch
#1 SSSW
Increase the number of final flag sequences:
When SW04 bit 2 is set to '1', the number of final flag sequences will be increased from 1 to 2
for a procedure signal (transmitted at 300 bps).
10. Closed Network Function: SW07 bit 7, bit 6, SW08 of Service Soft
Switch #1 SSSW
Set the closed network transmission function to 'Yes':
Set SW07 bit 7 to '1'.
Set the closed network reception function to 'Yes':
Set SW07 bit 6 to '1'.
Match the closed network ID:
Match the settings of SW08 bit 0 through bit 7.
On some models, you may make the closed network settings using the user soft switch and
register a closed network ID as part of user data.
11. Subaddress
A subaddress is used to indicate the location of a memory box in the other party (e.g., confiden-
tial mailbox, polling box), and it consists of 20 or fewer characters (numerals, *, #, space). As
log as the other party complies with the International Standards of ITU-T, the machine can
communicate with it by means of subaddresses.
At times, an ID number (referred to as a "password") is used to restrict access to a location
indicated by a subaddress.
With some models, polling based on subaddresses is called "selective polling," and a subaddress
used at time of polling is called a "selective polling address."
12. Password
A password used by a Canon facsimile machine may be any of the following:
Polling Password:
This is an ID number used for polling between Canon machines, and is also called a "polling
ID." Some models use 8 binary characters (00000000 through 11111111), while some ma-
chines use 3 decimal characters (000 through 255).
Password for Subaddress Communications:
This is an ID number used for a subaddress communication and, as in the case of a subaddress,
it consists of 20 or fewer characters (numerals, *, #, space).
Communication Password:
This is an ID number used for a password communication. Some models use 4 decimal charac-
ters (0000 through 9999), while some use 3 decimal characters (000 through 255).