Symptom
E025-0xa0/E025-0xb0 by attaching/ detaching the bottle
Symptom
Either of the error codes E025-0xa0/ E025-0xb0 occurred in field cases.
- E025-0xa0: Unable to detect the Release Holder Shift Cam HP Sensor status when opening the toner cap,
so that open and close status of the toner cap is unable to be judged. (x=1: Y, 2: M, 3: C, 4: Bk)
- E025-0xb0: Unable to detect the Release Holder Shift Cam HP Sensor status when closing the toner cap,
so that open and close status of the toner cap is unable to be judged. (x=1: Y, 2: M, 3: C, 4: Bk)
Cause
The above symptom may occur due to smearing with toner/ defect/ disconnected wire harness/ defective
PCB of the Release Holder Shift Cam HP Sensor. The photo [A] shows the Release Holder Shift Cam HP
Sensors for respective colors attached on the drive support plate.
[B] shows the Release Holder Shift Cam HP Sensor for black.