MAP1 IP Configuration Page 9 of 12
July 2021 • Rev. 1.2
Key section –
DO NOT
change
Factory default password. Please
modify to an appropriate password of
your choice other than the default
password.
Factory default IP address. Please
obtain a static IP address from IT
personnel and fill it here.
Factory default subnet mask. Please
specify the subnet mask where the
host computer is connected to.
Factory default gateway. Please
specify the gateway where the host
computer is connected to.
Factory default server port. You may
change it or leave it as default.
Factory default diagnostic port. You
may change it or leave it as default.
Factory default update port. You may
change it or leave it as default.
Specify if trusted host is enabled or
disabled. 1=enabled, 0=disabled
The IP address of the host computer
having the
First Access Express
software installed. If IpSecurity is
enabled and ClientIp has a valid IP
address specified then the MAP1
controller accepts data connection
(SrvPort 5000) from only this host
computer. Other connections on
DiagPort 5001 and UpdatePort
5002 are not affected by this setting.
Applicable for Cloud based controller.
The default hostname is cloudacs.com
The default retry interval in seconds