ELECTRICAL CONNECTION
The electrical connection of this appliance to the household electrical supply should be
undertaken by a competent electrician in accordance with the local regulations.
The mains cable must be positioned so that it does not come into contact with the hot
surfaces of the hob or the cabinet construction.
The hob must be installed in a way that ensures the cable is not under tension.
The Connectivity/Rating plate is mounted on the underside of the hob adjacent to the
Mains terminal block.
The connection to the household electrical supply must be made using an earthed terminal
or via an omnipolar circuit breaking device with a contact opening of at least 3mm.
In accordance with installation regulations, the appliance must have an accessible means
of isolation from the household electrical supply, for example: Suitable isolation switches,
circuit breakers, fuses etc.
Caution!
This appliance is only to be connected to a 220/240V~ 50/60Hz supply
Always connect the Earth Wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver.
Mains Connection Cable diameter
Cable protection Ampage
220/240V~ 50/60Hz
1 Phase + N
2 Phase
5 x 2,5 mm²
H 05 VV - F
H 05 RR - F
40 A *
400V~ 50/60Hz 2 Phase + N 5 x 2,5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz 3 Phase + N 5 x 2,5 mm²
H 05 VV - F
H 05 RR - F
16 A *
* calculated with the simultaneous factor following the standard EN 60 335-2-6
NORMAL UK CONNECTION