MINIMUM BURNER SETTING ADJUSTMENT
In the minimum position the flame must have a length of about 4 mm and must
remain lit even when turned quickly from the maximum position to minimum.
The flame adjustment is done in the following way:
- Turn on the burner
- Tum the tap to the MINIMUM position
- Take off the knob
- With a small flat screwdriver turn the screw inside the tap rod to the correct regula-
tion (fig. 3.5).
Normally for G30/G31, the regulation screw is tightened up.
Fig. 3.5