Downdraft Hood
Instruction Manual
DD903BK
& DD522BK
Contact Caple on 0117 938 7420 for spare parts or www.caple.co.uk

Questions and Answers

  • P
    Patrick DiazAug 17, 2025
    Why does my Caple DD903BK downdraft have low performance?
    • M
      Michael NortonAug 17, 2025
      The low performance of your Caple Ventilation Hood downdraft may be due to several reasons. Ensure that the motor speed selected is appropriate for the amount of fumes and vapors. Check that your kitchen is adequately ventilated to allow air intake. If you are using recirculation mode, the charcoal filter might be worn out. Also, verify that the air outlet channel is unobstructed and compliant. Finally, confirm that the non-return valves of the suctioning unit can rotate freely.
  • D
    Diana PerkinsAug 20, 2025
    What to do if my Caple DD903BK downdraft stops in the middle of operation?
    • R
      rperezAug 20, 2025
      If your Caple Ventilation Hood downdraft stops unexpectedly, first check if there is a power outage. Also, verify that the omnipolar device has not tripped.
  • J
    john77Aug 23, 2025
    How to fix a Caple DD903BK Ventilation Hood downdraft that does not work?
    • E
      Elizabeth CurtisAug 23, 2025
      If your Caple Ventilation Hood downdraft is not working, please check the following: * Ensure there is no power outage. * Make sure a specific speed setting has been selected. * Verify that the red reset key, located over the electrical system box, has been pressed.
  • B
    Bobby DavisAug 26, 2025
    Why does my Caple Ventilation Hood have low performance?
    • T
      Tyler TaylorAug 26, 2025
      If your Caple Ventilation Hood has low performance, make sure that: * The selected motor speed is adequate for the amount of fumes and vapors in the room. * The kitchen has enough ventilation for air intake. * The charcoal filter isn't worn out (if you have a filtering version). * The air outlet channel is unobstructed and compliant. * The suction unit's non-return valves can rotate freely.
  • C
    Crystal PriceAug 28, 2025
    What to do if my Caple DD903BK Ventilation Hood stops in the middle of operation?
    • O
      Olivia BurnsAug 28, 2025
      If your Caple Ventilation Hood stops during operation, verify that there isn't a power outage and that the omnipolar device hasn't tripped.
  • C
    connor50Aug 31, 2025
    How to fix a Caple DD903BK that does not work?
    • D
      davidstewartAug 31, 2025
      If your Caple Ventilation Hood isn't working, check the following: * Ensure there is no power outage. * Confirm that a specific speed setting has been chosen. * Press the red reset key located above the electrical system box.
  • S
    Suzanne MooreSep 3, 2025
    What to do if my Caple Ventilation Hood downdraft does not work?
    • T
      Tom DennisSep 3, 2025
      If your Caple Ventilation Hood downdraft isn't working, first check for a power outage. Then, ensure that you've selected a specific speed setting. Finally, check the red reset key located over the electrical system box and make sure it's pushed in.
  • M
    Matthew HallSep 5, 2025
    What to do if Caple Ventilation Hood downdraft stops in the middle of operation?
    • C
      Carol HerringSep 5, 2025
      If your Caple Ventilation Hood downdraft stops during operation, check for a power outage. Also, verify that the omnipolar device hasn't tripped.
  • M
    Michelle GreenSep 8, 2025
    Why is my Caple Ventilation Hood downdraft performing poorly?
    • M
      Matthew WardSep 8, 2025
      If your Caple Ventilation Hood downdraft isn't working as well as it should, consider these points: * Ensure the selected motor speed is appropriate for the amount of fumes and vapors. * Make sure the kitchen has adequate ventilation to allow air intake. * If you're using recirculation mode, check if the charcoal filter is worn out. * Verify the air outlet channel is unobstructed and compliant. * Confirm that the non-return valves of the suctioning unit can rotate freely.
  • K
    Kimberly CollinsSep 12, 2025
    How to fix a Caple Ventilation Hood downdraft that is not working?
    • L
      Leah WhiteSep 12, 2025
      If your Caple Ventilation Hood downdraft isn't working, please check the following: * Confirm there is no power outage. * Ensure that a specific speed setting has been selected. * Check that the red reset key, located on the electrical system box, is pushed.

Summary

Safety Instructions and Warnings

Appliance Description

Installation Guide

Downdraft Operation Modes

Recirculation Mode

Filter Maintenance

Electrical Connection

Electrical Safety Warnings

Important safety warnings related to electrical connection and power.

Electrical Connection Precautions

Precautions for connecting the appliance to the electrical network.

Electrical Danger Information

Critical safety information and danger warnings for electrical issues.

Operating the Downdraft Extractor

Grease Filter Saturation Indicator

Cleaning the Extractor

Grease Filter Cleaning

Procedure for cleaning and resetting grease filters.

Troubleshooting Common Issues

Overview

This document is an instruction manual for Caple downdraft extractors, specifically models DD903BK and DD522BK. It provides comprehensive information on the installation, operation, and maintenance of these appliances.

The Caple downdraft extractor is designed to remove unpleasant odours and cooking vapours from the kitchen. It can be installed to operate in either externally vented mode, discharging extracted air outside, or recirculation mode, where air is filtered and returned to the room. The appliance is intended for personal use in the home and is suitable for various domestic and similar applications, including staff kitchen areas in shops, offices, and other working environments, farmhouses, hotels, motels, other residential type environments, and bed and breakfast type environments.

Function Description:

The downdraft extractor features a push-button control panel for operation. It includes a motor speed indicator that uses four different colours to signify the set speed: white for first speed, green for second speed, blue for third speed, and red for fourth speed. The control panel also has a 10-minute timer function, which, when activated, turns off the motor and closes the front panel after 10 minutes. This function is indicated by the motor speed indicator flashing.

The appliance's top panel can be opened to an intermediate position of 45° or a full opening of 90°. When switched off, the first touch of the control button activates the top panel to the 45° opening, and the motor automatically sets to the second speed. A subsequent press will open the panel to 90°, maintaining the motor speed. Another press will stop the motor and completely close the top panel. For the DD522BK model, only the 90° opening of the glass top is possible, without the 45° intermediate opening.

The downdraft extractor is equipped with intelligent electronics that include a timer device for speed controls, particularly when the air capacity exceeds 650m³/h. For internal motor models with maximum air capacity higher than 650m³/h, the timer automatically switches the speed from fourth to third speed after 6 minutes of operation. External motor models also have a timer device that switches down the speed when it exceeds 650 m³/h. Remote motors with air capacity exceeding 650m³/h at both fourth and third speed will automatically switch from fourth to second speed after 6 minutes of operation. If the appliance is working at third speed, it automatically switches to second speed after 7 minutes of operation. The energy consumption in standby mode is lower than 0.5W. The appliance also features an automatic turn-off function, where it turns off automatically after 4 hours of continuous operation from the last setup.

Usage Features:

For optimal performance, it is recommended to use an air exhausting pipe with a maximum length of 5 meters and limit the number of elbows in the piping, as each elbow reduces air capacity. A 150mm constant diameter rigid ducting pipe should be used for the entire length. The appliance should not be used near hobs powered by wood or coal or with power levels that could damage the appliance. Adequate ventilation in the room is crucial when the cooker hood and other non-electric appliances are used simultaneously to prevent the hood from sucking combustion fumes. There must be a minimum space of 50mm between the edge of a gas hob and the downdraft frame.

Maintenance Features:

Regular maintenance is essential for correct operation and optimal performance. Before any cleaning or maintenance, the hood must be disconnected from the electrical network.

  • Cleaning External Surfaces and Accessories: Metallic scrubbers, abrasive products, or hard brushes should not be used. External surfaces and the light housing screen should be cleaned with commercially available household detergents diluted in water, then rinsed with clean water and dried with a soft cloth.
  • Grease Filters: The downdraft will signal grease filter saturation after 30 hours of operation, indicated by the flashing red LED speed indicator when the cooker hood is off. To reset this alarm, the "TIMER" button should be held down for at least 3 seconds while the carriage is open. Grease filters can be washed by hand or in the dishwasher and need to be cleaned regularly to prevent fire hazards. After cleaning, the grease filters and front panel must be refitted properly to ensure the downdraft functions correctly.
  • Active Charcoal Filter (Recirculation Mode Only): In recirculation mode, the active charcoal filter must be replaced periodically, on average every six months, to maintain effective use of the downdraft. To remove the charcoal filter, the grease filter must be removed first, then the plastic key of the charcoal filter panel should be pulled to disengage it. The steps are reversed to insert a new active charcoal filter.

The manual also provides troubleshooting tips for common issues such as the downdraft not working, low performance, or stopping during operation. For any anomalies, the appliance should be disconnected from the power supply. All repair charges will be incurred if the warranty card cannot be shown to Caple Service.

Caple DD903BK Specifications

General IconGeneral
ModelDD903BK
Width90 cm
Number of Speeds3
LightingLED
Finish/ColourBlack
Grease Filter TypeAluminium
Number of Motors1