Technical specifications
Operating voltage 24 V (16.8 to 32 V)
Load current max. 400 mA
Output pulse
dynamic
static
Approx. 300 ms
Corresponds to operating time
Reverse polarity protection Protection of all cables/lines
Short circuit protection Protected against short circuit and overload
Voltage drop max. 3 V at 400 mA
Power consumption at 24 V
with vibration
max. 30 mA
max. 130 mA
Operating temperature
dynamic
static
-30 °C (-22 °F) … +80 °C (176 °F)
0 °C (32 °F) … +55 °C (131 °F)
Degree of protection IP Front IP69K
Type of actuation Capacitive
Actuation force No actuation force required
max. altitude 2000 m above sea level with "CSA listing"
Relative air humidity max. 95%, non-condensing
Connection options
Plug
CHT3-_5_ …
Plug M8, 4-pin
CHT3-_5_ …
Plug M8, 5-pin