Integrated Control Solutions & Energy Savings
easy / easy compact / easy split
NO POWER
& SIGNAL
CABLES
TOGETHER
READ CAREFULLY IN THE TEXT!
User manual
electronic digital thermostats with defrost control

Questions and Answers:

Carel easy Specifications

General IconGeneral
BrandCarel
Modeleasy
CategoryThermostat
LanguageEnglish

Summary

User Manual Overview

Safety and Disposal Information

General Safety Warnings

Essential warnings for safe product operation and installation, including environmental precautions.

Product Disposal Guidelines

Instructions for environmentally responsible disposal of the equipment according to EU directives.

Product Introduction and Models

Main Characteristics and Features

Overview of key features across different controller models (easy, compact, split).

Product Model Range

Detailed descriptions of various PJEZ models (S, X, Y, C, M) and their applications.

Key Model Differences

Highlights distinctions in features and capabilities between easy, easy compact, and easy split models.

Probe Types and Accessories

Information on NTC/PTC probes and available accessories for the controllers.

Glossary of Definitions

Definitions of technical terms used throughout the manual.

Assembly and Installation

General Assembly Warnings

Precautions to avoid damage during installation in various environmental conditions.

Panel Mounting Procedures

Step-by-step guide for installing the unit into a panel using brackets or screws.

Electrical Connections

Instructions and warnings for making correct electrical connections for the devices.

Wiring Diagrams

Visual representations of electrical connections for different controller models.

Multiple Unit Wiring

Guidance for connecting multiple units via RS485 network using a converter.

User Interface and Start-up

Controller Display and Keypad Overview

Explanation of display elements, LEDs, and button functions for basic operation.

Easy Split Controller Interface

Specific display and keypad details for the easy split model.

Initial Configuration and Start-up

Steps for powering up the controller and performing preliminary configurations.

Keypad Operation Functions

How to perform common operations like set point adjustment and manual defrost.

Functions and Parameters

Temperature Probe Settings

Configuration of temperature measurement inputs, stability, and display rate.

Temperature Display Settings

Options for setting temperature units (°C/°F) and display format.

Temperature Control Modes

Configuration of direct/reverse operation, set point, and control differential.

Duty Setting Functionality

Safety function ensuring compressor operation during probe faults.

Compressor Protection Settings

Parameters to prevent compressor damage from frequent starts or stops.

Defrost Cycle Configuration

Detailed settings for managing defrost types, intervals, and durations.

Alarm Parameter Configuration

Settings for temperature, condenser, and digital input alarm thresholds and delays.

Digital Input Configuration

Assigning specific functions to the digital input based on its state.

Door Management Functions

Logic for managing door status, alarms, and fan/compressor behavior.

Evaporator Fan Control

Parameters for controlling evaporator fan operation based on temperature and compressor status.

Clock and Time Band Settings

Configuration of the Real Time Clock and time-based functions like defrost and night-time operation.

Parameter Set Selection (EZY)

Using the EZY function for quick selection of pre-defined parameter sets.

Auxiliary Output and Other Settings

Configuration of AUX relay, serial address, keypad, and buzzer functions.

Alarms and Parameters Tables

Alarm and Signal Reference

Table listing alarm codes, descriptions, associated parameters, and reset methods.

Alarm and Signal Descriptions

Detailed explanations of common alarm signals, their causes, and checks.

Data Error Handling

Information on how the instrument detects and handles saved data errors.

Parameter Modification and Reset

Procedures for navigating, modifying parameters, and resetting to default settings.

Parameter Tables by Model

Comprehensive parameter tables for easy, easy compact, and easy split models.

EZY Parameter Sets

Tables detailing EZY parameter set configurations for normal and low temperature models.

Troubleshooting Common Issues

Guide to identifying and resolving common operational problems and anomalous situations.

Technical Specifications

Easy Model Specifications

Detailed technical data including power, inputs, outputs, and operating conditions for easy models.

Easy Compact Model Specs

Detailed technical data including power, inputs, outputs, and dimensions for easy compact models.

Easy Split Model Specs

Detailed technical data for easy split models, including power board and terminal specifications.

Electromagnetic Compatibility

Compliance information regarding EU standards for electromagnetic compatibility.