EasyManua.ls Logo

Carlisle DeVilbiss PROLite Series - General Faults

Carlisle DeVilbiss PROLite Series
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
CAUSE
TROUBLESHOOTING MECHANICAL PERFORMANCE
Fluid nozzle or sprayhead
incorrectly fitted.
Replace with new needle.
Check fluid nozzle/needle
selection chart and fit correct
item.
Replace with new fluid nozzle.
Check for damage or blockage.
Paint build-up on air cap.
Thoroughly clean.
Gradual build-up of bounce-back
on gun head.
Replace with new air cap.
Unable to get round spray
GENERAL FAULTS
Check for damage or blockage.
CORRECTION
Will not spray.
No air pressure at gun.
Fluid nozzle/needle leakage.
Excessive needle wear.
Remove, check components for
damage and refit correctly.
Fluid needle adjustment knob
not open enough.
Excessive fluid nozzle wear.
Open fluid needle adjustment
knob.
Gun spits paint when triggering
on and off.
Incorrect needle fitted to gun.
Damaged air cap holes.
Paint build-up on fluid tip.
Fluid nozzle not fitted correctly
in gun head.
Check air supply and air line.
Tighten.
Tighten.
Fluid nozzle/needle leakage.
Gun spits paint when triggering
on due to paint build-up inside
air cap between spraying
operations.
Fluid nozzle not fitted correctly
in gun head.
SB-E-2-996 R1.0
15/24
www.carlisleft.com