62-11850 6
DISPLAY - CONTINUED
Display - 3 digits
• Box temperature
• "dF" message in defrost mode
• Malfunction messages
• Software version
• Hourmeter value
• Configuration parameters in the different menus
ON / OFF keys
These keys are for starting and stopping the unit.
SET key
This key is for accessing set point and unit data. This key will also allow
the user to enter into the Selection menu for the functional and defrost
parameters when combined with other keys.
MINUS & PLUS keys
These keys are for selecting the requested settings in different menus.
DEFROST key
This key enables manual defrost control.
°C / °F LED
This indicates that the unit is running and if temperature is displayed in
Celsius or Fahrenheit degrees.
REGULATION LED - Green
This indicates the three different modes:
• COOLING mode: green light is ON.
• NULL mode (regulation): green light is OFF.
• HEATING mode: green light flashing.
ALARM LED - Red
This LED will flash in case of a malfunction.