15 62-11850
PRODUCT LOADING
Before Loading
• Pre-cool the inside of the insulated body by lowering the tempera-
ture for about 15 minutes.
• Evacuate the humidity existing inside the box by carrying out a
manual defrost. This can only take place when enabled by the
defrost thermostat (box temperature lower than 37°F during pull
down and 46°F during heating).
• Evaporator fans are protected by safety grills. In the event of heavy
duty use of the unit, ice can accumulate on the grills. It is therefore
recommended to clean them regularly by means of a small brush.
The operation MUST be done when the unit has been SHUT DOWN.
When Loading
• Turn the unit off!
• It is recommended to open doors as little as possible to avoid the
intake of hot air and humidity.
• Select the temperature by means of the thermostat, according to
the transported goods.
• Check the internal temperature of the goods being loaded (using a
probe thermometer).
• Take care not to obstruct the air intakes on the evaporator section
and the ventilation ducts.
• Leave a free space of about 2 to 3 inches between the load and the
front wall.
• Leave a free space of about 8 inches between the top of the load
and the roof.
• Leave a free space of about 8 inches between the floor and the
load (gratings, pallets).
• Do not forget to close the doors.
• Before closing the doors, check your load once more and see that
nobody is shut inside the box.
For stationary utilization, we recommend to place the vehicle
in the shade.
Never leave your unit more than a month without running.