Go
,,ll_
UNU_
RED _LNU_
BLACK
BLUE
VERSION EN FRANCAIS INCLUS DANS MANUEL
D'INSTALLATION.
,HI_GND
x >_>_ LGNITOR
_L2
BURNER MOTOR
VALVE
>_ T OIL '_
PRIMARY
VALVE CAD CELL
STANDARD HEAT / COOL WIRING DIAGRAM WITH ELECTRONIC FAN TIMER.
OIL INPUT: 0.75 USOPH.
COOLING CAPACITY: 5 TONS MAX.
_: USE JUMPER ONLY WHEN THE COOLING AND HEATING SPEEDS ARE
SAME.
_ USE ONLY OIL PRIMARY CONTROL EQUIPPED WITH VALVE ON DELAY
(PRE PURGE) R7184B, P OR U.
_*_ USE CONSTANT IGNITION ONLY. NEVER USE THE INTERRUPTED IGNITION
AND/OR THE BLUE WIRE ON R7184 CONTROL.
FOR HUMIDIFIER, REMOVE THE DUMMY TERMINAL MARKED BUM.
FOR ELECTRONIC AIR CLEANER, REMOVE THE DUMMY TERMINAL MARKED EAC.
DNS 0925 Rev.A
OIL INPUT : 0.65 USGPH
COOLING CAPACITY : 2 1/2
to 5 TONS MAX
LO _ 3APACITOR
Oz
WHITK
L_kL_DS
BLACK
BLUE
OIL INPUT : 0.50 USOPH
COOLING CAPACITY : 2 TONS
1H(_) 115 VAC I_/60HZ POWER SUPPLY
LIMIT
Fig. 3--Wiring Diagram (I05-12) A03164