15
METHOD 2
USE (42) #8 x 3/4 (19 mm) SHEET
METAL SCREWS TYPICAL
FOR EACH STRAPS.THE
STRAPS SHOULD BE
VERTICAL AGAINST THE
FURNACE SIDES AND NOT
PULL AWAY FROM THE
FURNACE SIDES.
METHOD 1
FOLD ALL STRAPS UNDER
FURNACE AND SECURE WTH
(42) #8 x 3/4 (19 mm) SHEET METAL SCREWS
(2 SCREWS IN SIDE AND 2 SCREWS
IN BOTTOM).
A03176
Fig. 16 -- Horizontal Suspension with Straps
30-IN . (762mm) 
MIN WORK AREA
6 ″ M IN 
* 
TYPE-B 
VENT 
17  
3 
/ 
4 
″
22 
″
SHEET 
MET AL 
SEDIMENT 
TRAP 
EQUIPMENT MANU AL 
SHUT -OFF GAS  VA LV E  
LINE CONT A CT ONL Y PERMISSIBLE BETWEEN 
LINES FORMED BY INTERSECTIONS OF 
THE  T OP AND  TW O SIDES OF  THE FURNA CE 
JA CKET AND BUILDING JOISTS , 
STUDS , OR FRAMING. 
GAS 
ENTR Y 
17  
3 
/ 
4 
″ 
(451mm)
OVERALL
4  
3 
/ 
4 
″ 
(121mm) 
UNDER DOOR
1 ″ 
(25mm) 
UNDER   FURNACE
EXTEND OUT 12 ″ 
(305mm)
FR OM  FA CE OF DOOR 
*  WHEN USED  W ITH 
SINGLE  W ALL  VEN T 
CONNECTIONS 
UNION 
(152mm) 
(451mm)
(559mm) 
A03177
Fig. 17 -- Typical Attic Installation
Downflow
Furnaces
Connect supply--air duct to supply-- air outlet on furnace. Bend
flange inward past 90_ with wide duct pliers (See Fig. 14.) The
supply--air duct must be connected to ONLY the furnace supply
outlet or air conditioning coil casing (when used). When installed
on combustible material, supply--air duct must be connected to
ONLY the accessory subbase, KGASB0201ALL, or a factory
approved air conditioning coil casing. DO NOT cut main furnace
casing to attach supply side air duct, humidifier, or other
accessories. All accessories MUST be connected to duct external
to furnace casing.
58CV