4
CONTENTS (cont)
Page
Optional Pumpout System Maintenance . . . . . . . . . 81
OPTIONAL PUMPOUT COMPRESSOR OIL
CHARGE
OPTIONAL PUMPOUT SAFETY CONTROL
SETTINGS
Ordering Replacement Chiller Parts . . . . . . . . . . . . . 81
TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . 82-137
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Checking Display Messages. . . . . . . . . . . . . . . . . . . . . 82
Checking Temperature Sensors . . . . . . . . . . . . . . . . . 82
RESISTANCE CHECK
VOLTAGE DROP
CHECK SENSOR ACCURACY
DUAL TEMPERATURE SENSORS
Checking Pressure Transducers. . . . . . . . . . . . . . . . . 82
COOLER CONDENSER PRESSURE TRANSDUCER
AND OPTIONAL WATERSIDE FLOW DEVICE
CALIBRATION
TRANSDUCER REPLACEMENT
Control Algorithms Checkout Procedure . . . . . . . . 83
Control Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Control Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
RED LED (Labeled as STAT)
GREEN LED (Labeled as COM)
Notes on Module Operation . . . . . . . . . . . . . . . . . . . . 100
Chiller Control Module (CCM) . . . . . . . . . . . . . . . . . . 100
•INPUTS
OUTPUTS
Replacing Defective Processor Modules . . . . . . . 101
•INSTALLATION
Gateway Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . 102
DRIVE STATUS INDICATOR
MS STATUS INDICATOR
NET A STATUS INDICATOR
NET B STATUS INDICATOR
Physical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
APPENDIX — 19XRV LIQUIFLO™ 2 ICVC
PARAMETER INDEX. . . . . . . . . . . . . . . . . . . . . . 138-146
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
INITIAL START-UP CHECKLIST FOR
19XRV HERMETIC CENTRIFUGAL
LIQUID CHILLER . . . . . . . . . . . . . . . . . . . .CL-1 to CL-12
INTRODUCTION
Prior to initial start-up of the 19XRV unit, those involved in
the start-up, operation, and maintenance should be thoroughly
familiar with these instructions and other necessary job data.
This book is outlined to familiarize those involved in the
start-up, operation, and maintenance of the unit with the con-
trol system before performing start-up procedures. Procedures
in this manual are arranged in the sequence required for proper
chiller start-up and operation.
ABBREVIATIONS AND EXPLANATIONS
Frequently used abbreviations in this manual include:
Words printed in all capital letters or in italics may be
viewed on the International Chiller Visual Controller (ICVC)
(e.g., LOCAL, CCN, ALARM, etc.).
Words printed in both all capital letters and italics can also
be viewed on the ICVC and are parameters (e.g., CONTROL
MODE, COMPRESSOR START RELAY, ICE BUILD
OPTION, etc.) with associated values (e.g., modes, tempera-
tures, percentages, pressures, on, off, etc.).
Words printed in all capital letters and in a box represent
softkeys on the ICVC control panel (e.g., , ,
, , etc.).
This unit uses a microprocessor control system. Do not
short or jumper between terminations on circuit boards or
modules; control or board failure may result.
Be aware of electrostatic discharge (static electricity) when
handling or making contact with circuit boards or module
connections. Always touch a chassis (grounded) part to
dissipate body electrostatic charge before working inside
the VFD enclosure.
Use extreme care when handling tools near boards and
when connecting or disconnecting terminal plugs. Circuit
boards can easily be damaged. Always hold boards by the
edges and avoid touching components and connections.
This equipment uses, and can radiate, radio frequency
energy. If not installed and used in accordance with the
instruction manual, it may cause interference to radio
communications. It has been tested and found to comply
with the limits for a Class A computing device pursuant to
Subpart J of Part 15 of FCC Rules, which are designed to
provide reasonable protection against such interference
when operated in a commercial environment. Operation of
this equipment in a residential area is likely to cause
interference, in which case the user, at his own expense,
will be required to take whatever measures may be
required to correct the interference.
Always store and transport replacement or defective boards
in anti-static shipping bag.
CCM Chiller Control Module
CCN Carrier Comfort Network®
CCW Counterclockwise
CW Clockwise
ECDW Entering Condenser Water
ECW Entering Chilled Water
EMS Energy Management System
HGBP Hot Gas Bypass
I/O Input/Output
ICVC International Chiller Visual Controller
LCD Liquid Crystal Display
LCDW Leaving Condenser Water
LCW Leaving Chilled Water
LED Light-Emitting Diode
OLTA Overload Trip Amps
PIC III Product Integrated Controls III
RLA Rated Load Amps
SI International System of Units
TXV Thermostatic Expansion Valve
VFD Variable Frequency Drive
ENTER EXIT
INCREASE QUIT

Table of Contents

Other manuals for Carrier 19XRV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 19XRV and is the answer not in the manual?

Carrier 19XRV Specifications

General IconGeneral
Model19XRV
CategoryChiller
RefrigerantR-134a
EfficiencyHigh
Dimensions (L x W x H)Varies by model
TypeCentrifugal
Compressor TypeHermetic Two-stage
Full Load Efficiency0.50 kW/Ton
Part Load Efficiency0.30 kW/ton (at AHRI conditions)
WeightVaries by model
Voltage Options600V
Operating Temperature Range40°F - 120°F