DETAILED COOLING CAPACITIES
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES deg F
75 85 95 105 115 125
CFM EWB
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
KW**
To t a l
Sens
To t a l
Sens
To t a l
Sens
To t a l
Sens
To t a l
Sens
To t a l
Sens
24ABA442A30 Outdoor Section With CAP**4821A** Indoor Section
1225
72 48.69 25.68 2.57 46.44 24.82 2.93 44.08 23.93 3.33 41.59 23.01 3.79 38.92 22.03 4.34 36.24 21.06 4.88
67 44.08 31.40 2.60 42.00 30.53 2.95 39.82 29.63 3.35 37.54 28.70 3.81 35.09 27.71 4.39 32.52 26.69 4.98
62 40.13 37.15 2.61 38.27 36.26 2.96 36.35 35.33 3.35 34.37 34.37 3.81 32.57 32.57 4.40 30.57 30.57 5.00
57 39.17 39.17 2.61 37.67 37.67 2.96 36.09 36.09 3.35 34.41 34.41 3.81 32.57 32.57 4.40 30.57 30.57 5.00
1400
72 49.63 26.97 2.62 47.28 26.10 2.98 44.82 25.19 3.38 42.24 24.26 3.84 39.47 23.26 4.38 36.72 22.29 4.90
67 44.93 33.44 2.65 42.75 32.56 3.00 40.50 31.65 3.40 38.13 30.70 3.86 35.60 29.69 4.43 32.98 28.65 5.02
62 41.12 39.90 2.66 39.26 38.92 3.01 37.52 37.52 3.41 35.73 35.73 3.87 33.77 33.77 4.46 31.68 31.68 5.04
57 40.82 40.82 2.66 39.21 39.21 3.01 37.52 37.52 3.41 35.73 35.73 3.87 33.77 33.77 4.46 31.68 31.68 5.04
1575
72 50.34 28.18 2.68 47.90 27.30 3.03 45.37 26.38 3.43 42.70 25.43 3.88 39.87 24.43 4.42 37.06 23.45 4.91
67 45.57 35.39 2.70 43.33 34.49 3.05 41.01 33.57 3.46 38.58 32.60 3.92 35.99 31.57 4.48 33.34 30.50 5.07
62 42.20 42.20 2.71 40.50 40.50 3.06 38.71 38.71 3.46 36.82 36.82 3.92 34.75 34.75 4.50 32.59 32.59 5.08
57 42.20 42.20 2.71 40.50 40.50 3.06 38.72 38.72 3.46 36.82 36.82 3.92 34.76 34.76 4.50 32.59 32.59 5.08
Multipliers for determining the performance with other indoor sections.
Cooling
Indoor Model
Capacity Power Furnace Model
*CAP**4821A** 1.00 1.00
CAP**4221A** 0.98 1.00
CAP**4224A** 0.98 0.98
CAP**4817A** 1.01 1.01
CAP**4824A** 1.00 0.96
CNPF*4818A** 0.99 0.95
CNPH*4221A** 0.99 0.91
CNPH*4821A** 1.00 1.00
CNPV*4221A** 0.99 0.99
CNPV*4821A** 1.00 1.00
CNPV*4824A** 1.00 0.96
CSPH*4212A* * 1.00 1.00
CSPH*4812A* * 1.01 0.97
FV4BNB006 1.02 0.91
FV4BNF003 0.98 0.90
FV4BNF005 1.01 0.90
FX4CN(B,F)042 1.00 0.96
FX4CN(B,F)048 1.00 0.92
FY4ANF042 0.99 1.01
FY4ANF048 1.01 1.01
CNPH*4221A** 0.98 0.85 58CV(A,X)070 ---12
CNPH*4821A** 0.99 0.95 58CV(A,X)070 ---12
CSPH*4212A* * 0.99 0.95 58CV(A,X)070 ---12
CSPH*4812A* * 0.99 0.95 58CV(A,X)070 ---12
CAP**4817A** 1.01 0.97 58CV(A,X)090 ---16
CAP**4221A** 0.99 0.95 58CV(A,X)110 ---20
CAP**4821A** 0.99 0.86 58CV(A,X)110 ---20
CNPV*4221A** 1.00 0.92 58CV(A,X)110---20
CNPV*4821A** 1.01 0.97 58CV(A,X)110---20
CAP**4224A** 0.99 0.95 58CV(A,X)135 ---22
CAP**4824A** 1.01 0.88 58CV(A,X)135 ---22
CNPV*4824A** 1.01 0.93 58CV(A,X)135---22
CAP**4224A** 0.98 0.93 58MVB040---14
CAP**4824A** 0.98 0.85 58MVB040---14
CNPH*4221A** 0.99 0.95 58MVB040---14
CNPH*4821A** 0.99 0.95 58MVB040---14
CNPV*4824A** 0.99 0.95 58MVB040---14
CSPH*4212A* * 0.99 0.95 58MVB040---14
CSPH*4812A* * 0.99 0.86 58MVB040---14
CAP**4817A** 0.99 0.91 58MVB060---14
CAP**4221A** 0.96 0.96 58MVB080---14
CAP**4821A** 0.99 0.86 58MVB080---14
CNPV*4221A** 0.98 0.93 58MVB080---14
CNPV*4821A** 0.99 0.95 58MVB080---14
CAP**4221A** 0.99 0.99 58MVB080---20
CAP**4221A** 0.99 0.99 58MVB100---20
CAP**4224A** 0.99 0.95 58MVB120---20
See notes on pg. 20